Randomized study of digital single-operator cholangioscope compared to fiberoptic single-operator cholangioscope in a novel cholangioscopy bench model

Author:

Shah Raj1,Neuhaus Horst2,Parsi Mansour3,Reddy D.4,Pleskow Douglas5

Affiliation:

1. Gastroenterology, University of Colorado, Aurora, Colorado, United States

2. Gastroenterology, Evangelisches Krankenhaus, Dusseldorf, Dusseldorf, Germany

3. Gastroenterology, Cleveland Clinic Foundation, Cleveland, United States

4. Gastroenterology, Asian Institute of Gastroenterology, Hyderabad, India

5. Gastroenterology, Beth Israel Deaconess Medical Center, Boston, United States

Abstract

Abstract Background and study aims Cholangiopancreatoscopy is utilized for diagnosis and therapy of pancreaticobiliary disorders. a fully-disposable, digital, single-operator cholangioscope (DSOC) was developed with high image resolution and wide field-of-view. This bench study compared the new DSOC to the previous semi-disposable, fiber-optic cholangioscope (FSOC) prior to the clinical availability of the DSOC system. Methods Five experts performed one practice run followed by randomized runs comparing DSOC to FSOC in a biliary tract model consisting of three fixed left-intrahepatic tracts (LIHD), and variable common bile duct (CBD) and right-intrahepatic tracts (RIHD) with seven total lesions in multiple configurations. Timed runs aimed to visualize and target each lesion using miniature biopsy forceps. Definitions: visual success, visualizing targets; targeting success, touching target with forceps; complete run, touching seven targets within 20 minutes. Image quality, ease-of-use, and time to completion were recorded. Results Thirty-seven evaluable runs (20 DSOC, 17 FSOC) were completed. DSOC was superior to FSOC in Visual (99 % vs. 67 %, P < 0.001) and targeting success (6.6 vs. 4.5, P = 0.009), proportion of complete runs (13 /20 vs. 0 /17, P < 0.001) and time of run (10.1 min vs. 15.4 min, P < 0.001). For fixed LIHD, DSOC achieved higher targeting success compared to FSOC (2.6 vs. 1.1, P < 0.001) with no difference in RIHD and CBD targets (4.0 vs. 3.4, P = 0.39). Investigators reported superior image quality and ease-of-use with DSOC. Conclusions In this model, DSOC performed superiorly to FSOC in image quality, visualization, and maneuverability. The model could potentially be utilized for training endoscopists less experienced with cholangiopancreatoscopy.

Publisher

Georg Thieme Verlag KG

Subject

Gastroenterology,Medicine (miscellaneous)

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3