Metallic vs plastic stents to treat biliary stricture after liver transplantation: a systematic review and meta-analysis based on randomized trials

Author:

Visconti Thiago Arantes de Carvalho1,Bernardo Wanderley Marques1,Moura Diogo Turiani Hourneaux1,Moura Eduardo Turiani Hourneaux1,Gonçalves Caio Vinicius Tranquillini1,Farias Galileu Ferreira1,Guedes Hugo Gonçalo1,Ribeiro Igor Braga1,Franzini Tomazo Prince1,Luz Gustavo Oliveira1,dos Santos Marcos Eduardo dos Lera1,de Moura Eduardo Guimarães Hourneaux1

Affiliation:

1. Department of Gastroenterology, Hospital das Clinicas from University of São Paulo Medical School, São Paulo, Brazil

Abstract

Abstract Background and study aims The first-line approach to anastomotic biliary stricture after orthotopic liver transplantation (OLTX) involves endoscopic retrograde cholangiopancreatography (ERCP). The most widely used technique is placement of multiple plastic stents, but discussions are ongoing on the benefits of fully-covered self-expandable metallic stents (FCEMS) in this situation. This study aimed to compare results from use of plastic and metal stents to treat biliary stricture after transplantation. Patients and methods Searches were performed in the Medline, EMBASE, SciELO/LILACS, and Cochrane databases, and only randomized studies comparing the two techniques were included in the meta-analysis. Results Our study included four randomized clinical trials totaling 205 patients. No difference was observed between the stricture resolution rate (RD: 0.01; 95 %CI [−0.08 – 0.10]), stricture recurrence (RD: 0.13; 95 %CI [−0.03 – 0.28]), and adverse events (RD: −0.10; 95 %CI [−0.65 – 0.44]) between the plastic and metallic stent groups. The metallic stent group demonstrated benefits in relation to the number of ERCPs performed (MD: −1.86; 95 %CI [−3.12 to −0.6]), duration of treatment (MD: −105.07; 95 %CI [−202.38 to −7.76 days]), number of stents used (MD: −10.633; 95 %CI [−20.82 to −0.44]), and cost (average $ 8,288.50 versus $ 18,580.00, P < 0.001). Conclusions Rates of resolution and recurrence of stricture are similar, whereas the number of ERCPs performed, number of stents used, duration of treatment, and costs were lower in patients treated with FCEMS, which shows that this device is a valid option for initial treatment of post-OLTX biliary stricture.

Publisher

Georg Thieme Verlag KG

Subject

Gastroenterology,Medicine (miscellaneous)

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3