Comparison of Microwave and Radiofrequency Ablation for the Treatment of Small- and Medium-Sized Hepatocellular Carcinomas in a Prospective Randomized Trial

Author:

Vogl Thomas J.1,Martin Simon S.1,Gruber-Rouh Tatjana1,Booz Christian1,Koch Vitali1,Nour-Eldin Nour-Eldin A.12,Hussainy Said M. N.1

Affiliation:

1. Department of Diagnostic and Interventional Radiology, University Hospital Frankfurt, Germany

2. Department of Diagnostic and Interventional Radiology, Cairo University, Faculty of Medicine, Cairo, Egypt

Abstract

Purpose To compare the therapeutic response and clinical outcome of CT-guided percutaneous microwave (MWA) and radiofrequency ablation (RFA) for the treatment of small- and medium-sized HCC. Materials and Methods In this prospective trial, 50 patients with HCC were randomly assigned to MWA or RFA treatment. MRI was performed 24 h before and after ablation and subsequently in 3-month intervals. Ablation volumes, ablation durations, adverse events (AE), technique efficacy, technical success, local tumor progression (LTP), disease-free survival (DFS), intrahepatic distant recurrence (IDR), and overall survival (OS) rates were evaluated. Results The mean ablation volume was 66.5 cm³ for MWA and 29.2  cm³ for RFA (p < 0.01). The mean ablation durations for MWA and RFA were 11.2 ± 4.0 min and 16.3 ± 4.7 min, respectively (p < 0.01). Six mild AEs were documented (p > 0.05). All treatments had a technical success rate and a technique efficacy rate of 100 % (50/50, p = 1.00). LTP within 2 years occurred in 1/25 (4 %) in the MWA group and in 4/25 (16 %) in the RFA group (p = 0.06). IDR within 2 years was 8/25 (32 %) for MWA and 14/25 (56 %) for RFA (p < 0.05). The median DFS was 24.5 months and 13.4 months for MWA and RFA, respectively (p = 0.02). The 1-, 2-, 3-year OS rates were 100 %, 80 %, 72 % in the MWA group and 72 %, 64 %, 60 % in the RFA group, respectively (p ≥ 0.14). Conclusion The clinical outcome after MWA or RFA for HCC treatment was very similar with no significant differences in LTP or OS. However, MWA shows a trend toward better DFS with fewer IDRs than RFA. Key Points: 

Publisher

Georg Thieme Verlag KG

Subject

Radiology, Nuclear Medicine and imaging

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3