Outcomes of use of electromagnetic guidance with responsive insertion technology (RIT) during colonoscopy: a prospective randomized controlled trial

Author:

Peter Shajan1,Reddy Nipun1,Naseemuddin Mohammed1,Zaibaq Jenine1,McGwin Gerald2,Wilcox C.1

Affiliation:

1. Gastroenterology and Hepatology, University of Alabama at Birmingham, Birmingham, Alabama, United States

2. Epidemiology, University of Alabama at Birmingham, Birmingham, Alabama, United States

Abstract

Abstract Background and study aims Colonoscopy can be technically challenging and cause discomfort in patients. The integrated Scope Guide assist is built in to show that with its use outcomes are improved during colonoscopy. We aimed to test the usefulness of the Magnetic Scope Guide Assist (ScopeGuide) with respect to cecal intubation time, and other procedural quality outcomes. Patients and methods We conducted a prospective study of outpatients undergoing elective colonoscopy at the endoscopic units of the University of Alabama at Birmingham (UAB) from March 2016 to July 2016. Patients were randomly assigned in a 1:1 block design to groups that either had standard colonoscopy or Scope-guided colonoscopy. The primary outcome measure was cecal intubation time (CIT). Secondary outcome measures included use of manual pressure, position changes for cecal intubation and sedation requirements. Results Three hundred patients were randomized to either group; standard (n = 150) vs. Scope-guided (n = 150). The mean CIT was not statistically different for the standard and the Scope-guided groups (4.6 vs. 4.3 minutes; P = 0.46). There were also no statistical differences in frequency of manual pressure applied (16.7 % for Scope-guided vs. 19.1 % for standard; P = 0.65) or position changes (11.4 % for scope guided vs. 8.8 % standard; P = 0.56). Sedation requirements showed lesser use of midazolam (3.9 mg vs. 4.7 mg, P = 0.003) in the Scope-guide group, while there was no significant difference in use of fentanyl (fentanyl – 62.1 mg vs. 68.9 mg, P = 0.09 similar between groups, for Scope-guided vs. standard groups, respectively). Adverse events were similar in both groups. Conclusions In patients undergoing routine elective colonoscopy, use of ScopeGuide by experienced colonoscopists did not improve CIT or affect the frequency of ancillary maneuvers. The benefit of this device during training of endoscopists could be considered for further studies.

Publisher

Georg Thieme Verlag KG

Subject

Gastroenterology,Medicine (miscellaneous)

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3