Sixteen-Frame Gated Myocardial Perfusion SPECT as a Surrogate for Equilibrium Radionuclide Angiography in Measurement of Systolic and Diastolic Indices: A Cross-Sectional Study

Author:

Hosseinnezhad Ariani Toktam1ORCID,Ghodsirad Mohammadali2,Hosseinnejad Ariani Faezeh3,Poorzand Hoorak4,Sadeghi Ramin5,Dabbagh Kakhki Vahid Reza5ORCID

Affiliation:

1. Nuclear Medicine Research Center, Mashhad University of Medical Sciences, Mashhad, Iran

2. Department of Nuclear Medicine, Shohada Tajrish Hospital, School of Medicine, Shahid Beheshti University of Medical Sciences, Tehran, Iran

3. Metabolomics and Genomics Research Center, Endocrinology and Metabolism Molecular-Cellular Sciences Institute, Tehran University of Medical Sciences, Tehran, Iran

4. Department of Cardiovascular, Imam Reza Hospital, Mashhad University of Medical Sciences, Mashhad, Iran

5. Department of Nuclear Medicine, Ghaem Hospital, Mashhad University of Medical Sciences, Mashhad, Iran

Abstract

Abstract Introduction Equilibrium radionuclide angiography (ERNA) has long been assumed as the preferred method to assess cardiac volumes as well as left ventricular systolic and diastolic indices. ERNA was used to diagnose subtle changes in cardiac function during chemotherapy or early stages of heart failure. Gated myocardial perfusion SPECT (GMPS) was introduced as a more feasible and versatile alternative to ERNA, but the precision of GMPS to assess systolic and diastolic indices has not yet been fully reviewed. Method We studied the left ventricular systolic and diastolic functional indices measured by a 16-frame GMPS and compared the results with those of ERNA in 25 patients. All the images were analyzed visually, semi-quantitatively, and quantitatively using quantitative gated SPECT (QGS), quantitative blood pool SPECT (QBS), and planar gated blood pool (PGBP) software. The left ventricular functional indices calculated using QGS compared with those obtained using QBS and PGBP Result Our study found a significant correlation between the left ventricular ejection fraction (LVEF) calculated using the PGBP, QGS, and QBS methods. There was a significant correlation between the LV peak ejection rate (LVPER) calculated by the PGBP and QGS analyses, and there was no significant difference in the LVPER calculated with the QGS and QBS methods. This study also revealed a significant correlation between the LV peak filling rate (LVPFR) calculated by QBS and QGS, with no significant difference between them. We also found a significant correlation between LV end systolic volume (LVESV) calculated using QGS and QBS and between LV end diastolic volume (LVEDV) calculated using QGS and QBS software. This study also revealed a significant correlation between the LV mean filling rate over the first third of diastole (LVMFR/3) calculated using the QGS and QBS software. Conclusion Considering the significant correlation between LVEF, LVPER, LVPFR, LVESV, LVMFR/3, and LVEDV calculated using the QGS and QBS methods in our study, the 16-frame GMPS could be regarded as an acceptable substitute for ERNA in the investigation of systolic and diastolic indices.

Publisher

Georg Thieme Verlag KG

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3