Three-Dimensional Analysis of Polyaxial Volar Locking Plate Position for Distal Radius Fracture

Author:

Eda Yusuke12,Kohyama Sho3,Ikumi Akira4,Ishii Tomoo2,Yamazaki Masashi4,Yoshii Yuichi2

Affiliation:

1. Department of Orthopaedic Surgery, Tsukuba Medical Center, Tsukuba, Ibaraki, Japan

2. Department of Orthopaedic Surgery, Tokyo Medical University Ibaraki Medical Center, Inashiki, Ibaraki, Japan

3. Department of Orthopaedic Surgery, Kikkoman General Hospital, Noda, Chiba, Japan

4. Department of Orthopaedic Surgery, Institute of Medicine, University of Tsukuba, Tsukuba, Ibaraki, Japan

Abstract

Abstract Background To avoid screw penetration into the joint when using the polyaxial volar locking plate (VLP) for osteosynthesis of distal radius fractures, it is important to note that the optimal screw insertion angles depending on the plate positions. Purpose The purpose of this study was 2-fold: first, to evaluate the differences of the most distal plate position where the screw does not penetrate into the joint in the three-dimensional (3D) radius models; second, to evaluate the relationship between the plate position and the transverse diameter of the distal radius. Patients and Methods Thirty plain X-rays and computed tomography (CT) scans of healthy wrists were evaluated. The transverse diameter was measured on plain X-rays. 3D radius models were reconstructed from CT data. A 3D image of polyaxial VLP was used to investigate the most distal plate position at three different screw insertion angles. The linear distance between the volar articular edge and the plate edge was measured and compared among different screw insertion angles. The correlations between the plate positions and the transverse diameter were also evaluated. In addition, the relationship between the most distal screw place and articular surface was confirmed with one case of distal radius fracture. Results The optimal positions relative to the neutral were 2.7 mm proximal in the distal swing and 1.9 mm distal in the proximal swing. The linear distance was significantly correlated with the transverse diameter in each group. It was confirmed that the relationship between the most distal screw place and articular surface was applicable in the actual case. Conclusion The results showed that the most distal position of the polyaxial VLP differed depending on the screw insertion angle and became more proximal as the transverse diameter increased. These results may be useful as a reference for preoperative planning. Levels of Evidence III.

Publisher

Georg Thieme Verlag KG

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3