Background Hemophilia A (HA) is an inherited bleeding disorder caused by a deficiency or defect in factor VIII (FVIII). Methods We investigated the role of clot waveform analysis (CWA) of activated partial thromboplastin time in the diagnosis and therapeutic monitoring of HA. The changes in CWA parameters the maximum clotting velocity (|Min1|), maximum clotting acceleration (|Min2|), and maximum clotting deceleration (|Max2|) were detected among mild, moderate, and severe HA groups. Results As the severity of HA subtypes increased, the levels of |Min1|, |Min2|, and |Max2| progressively decreased (p < 0.05). Receiver operating characteristic curve analysis showed that |Max2| and |Min2| were more effective than |Min1| in distinguishing different types of HA patients, with higher diagnostic efficacy. The standard curves based on Actin FSL reagent for normal and low levels of FVIII:C-|Max2| were established, with R2 values of 0.98 and 0.99, respectively. These curves can be utilized for monitoring during replacement therapies involving full-length recombinant FVIII and B-domain-deleted FVIII. Thirty cases of HA patients utilized the FVIII-|Max2| standard curve to obtain individual pharmacokinetics characteristic parameters. The clearance, half-life (t1/2), time to FVIII:C of 1% above baseline (tt1%), and predicted dosage showed no statistically significant differences compared with one-stage assay (p > 0.05). Conclusion CWA is an economical and practical tool, and its related parameters are associated with the severity of HA. It has promising clinical prospects in predicting FVIII:C levels and individualized treatment when HA patients undergo replacement therapy.

Funder

Clinical Trials from the Affiliated Drum Tower Hospital, Medical School of Nanjing University

Ministry of Science and Technology of the People's Republic of China

National Key Research and Development Program of China

National Natural Science Foundation of China

Publisher

Georg Thieme Verlag KG

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3