Abstract

Abstract Objectives In this paper, an artificial intelligence-based algorithm for predicting the optimal contrast medium dose for computed tomography (CT) angiography of the aorta is presented and evaluated in a clinical study. The prediction of the contrast dose reduction is modelled as a classification problem using the image contrast as the main feature. Methods This classification is performed by random decision forests (RDF) and k-nearest-neighbor methods (KNN). For the selection of optimal parameter subsets all possible combinations of the 22 clinical parameters (age, blood pressure, etc.) are considered using the classification accuracy and precision of the KNN classifier and RDF as quality criteria. Subsequently, the results of the evaluation were optimized by means of feature transformation using regression neural networks (RNN). These were used for a direct classification based on regressed Hounsfield units as well as preprocessing for a subsequent KNN classification. Results For feature selection, an RDF model achieved the highest accuracy of 84.42% and a KNN model achieved the best precision of 86.21%. The most important parameters include age, height, and hemoglobin. The feature transformation using an RNN considerably exceeded these values with an accuracy of 90.00% and a precision of 97.62% using all 22 parameters as input. However, also the feasibility of the parameter sets in routine clinical practice has to be considered, because some of the 22 parameters are not measured in routine clinical practice and additional measurement time of 15 to 20 minutes per patient is needed. Using the standard feature set available in clinical routine the best accuracy of 86.67% and precision of 93.18% was achieved by the RNN. Conclusion We developed a reliable hybrid system that helps radiologists determine the optimal contrast dose for CT angiography based on patient-specific parameters.

Funder

The German Federal Ministry of Education and Research

Publisher

Georg Thieme Verlag KG

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3