Evaluation of a new stent for EUS-guided pancreatic duct drainage: long-term follow-up outcome

Author:

Matsunami Yukitoshi1,Itoi Takao1,Sofuni Atsushi1,Tsuchiya Takayoshi1,Kamada Kentaro1,Tanaka Reina1,Tonozuka Ryosuke1,Honjo Mitsuyoshi1,Mukai Shuntaro1,Fujita Mitsuru1,Yamamoto Kenjiro1,Asai Yasutsugu1,Kurosawa Takashi1,Tachibana Shingo2,Nagakawa Yuichi2

Affiliation:

1. Department of Gastroenterology and Hepatology, Tokyo Medical University, Tokyo, Japan

2. Department of Gastrointestinal and Pediatric Surgery, Tokyo Medical University, Tokyo, Japan

Abstract

Abstract Background and study aims Endoscopic ultrasonography-guided pancreatic duct drainage (EUS-PD) has been reported as an alternative for failed conventional endoscopic retrograde cholangiopancreatography (ERCP). However, there are few dedicated devices for EUS-PD. Recently, we have developed a new plastic stent dedicated to EUS-PD and have conducted a feasibility study to evaluate its efficacy. In the current study, we evaluated the long-term efficacy of this new plastic stent. Patients and methods Thirty patients (61 ± 14.3 years old, 14 men) with acute recurrent pancreatitis caused by a stricture in the main pancreatic duct (MPD) or stenotic pancreatoenterostomy were treated at our institution using our recently developed 7Fr plastic stent between August 2013 and April 2017. Results The stent was placed successfully in all patients (30/30) and early clinical success was achieved in all of them. Early adverse events (AEs) occurred in seven patients (23.3 %), namely, self-limited abdominal pain (n = 5), mild pancreatitis (n = 1), and bleeding which required transcatheter arterial embolization (n = 1). Two patients died of primary disease and three were lost to follow-up. The remaining 25 patients were followed up after initial EUS-PD for a median of 23 months (range, 6 – 44 months). Twenty patients required regular stent exchange (3 times; range, 1 – 12 times). Spontaneous stent dislodgement was observed in six patients. Four patients wanted their stents removed 1 year after the initial intervention. Twelve patients (48 %) had regular stent exchange 1 year after the initial intervention. Three patients converted to standard transpapillary pancreatic duct stenting by conventional ERCP. Finally, nine patients (36 %) had complete stent removal either intentionally or by spontaneous dislodgement without any symptoms. Conclusion The new plastic stent for EUS-PD was associated with not only short-term technical success but also long-term clinical success in the majority of patients evaluated in this study.

Publisher

Georg Thieme Verlag KG

Subject

Gastroenterology,Medicine (miscellaneous)

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3