The Normal Active Range of Motion of the Index, Middle, Ring, and Little Fingers in a Sample of Indian Population

Author:

B.K Mohamed Ibrahim1ORCID,Baba P. Umar Farooq2ORCID,Singh Veena3ORCID,Karanjkar Ankur4ORCID,Madhavan Latha1,Shah Raheeb Ahmad5,Haq Ansarul3ORCID,Pawar Manoj4ORCID,Kumari Anupama3,Panse Nikhil4,G. Vishnubabu1,Pandian Shyamnath Krishna1,Sharma Anirudha1ORCID,Krishnamoorthy Rajagopalan1,Thatte Mukund6,Bhat Anil7,Krishnamoorthy Sridhar1

Affiliation:

1. Institute of Craniofacial and Aesthetic Plastic Surgery, SIMS Hospital, Chennai, Tamil Nadu, India

2. Department of Plastic Surgery, Sher-I-Kashmir Institute of Medical Sciences , Srinagar, Jammu and Kashmir, India

3. Department of Plastic Surgery, All India Institute of Medical Sciences, Patna, Bihar, India

4. Department of Plastic Surgery, Byramjee Jeejeebhoy Government Medical College, Pune, Maharashtra, India

5. Department of Plastic Surgery, Sher-I-Kashmir Institute of Medical Sciences, Srinagar, Jammu and Kashmir, India

6. Department of Plastic Surgery, Bombay Hospital, Mumbai, Maharashtra, India

7. Department of Hand Surgery, Kasturba Medical College, Manipal, Karnataka, India

Abstract

Abstract Background The normative data for finger range of motion (ROM) are not available for the Indian population. The aim of our study was to measure the active ROM of finger joints in normal healthy volunteers in a sample of Indian population. Materials and Methods This is a prospective observational study conducted as a part of the Indian normative data project of the Indian Society for Surgery of the Hand (ISSH). The study included one participating center from four geographical regions of the country. Certified goniometers were used to measure the ROM of fingers in all centers. A standardized methodology was devised. A pilot study was done to assess the interobserver and intraobserver reliability, following which data were collected by one measurement. Results This pilot study was performed in 20 hands that showed good interobserver and intraobserver reliability correlation. A total of 390 hands were measured in four participating centers. Active flexion of metacarpophalangeal (MCP) joint was the highest in the middle finger (86.6 ± 10.4 degrees) followed by the index finger (86.0 ± 9.2 degrees), little finger (85.0 ± 8.4 degrees), and ring finger (84.2 ± 8.6 degrees). The index finger (97.2 ± 16.9 degrees) showed maximum proximal interphalangeal (PIP) joint flexion followed by the middle finger (96.2 ± 15.8 degrees), ring finger (96.0 ± 15.9 degrees), and little finger (91.8 ± 12.7 degrees). Distal interphalangeal (DIP) joint flexion increased from the index finger (81.6 ± 13.9 degrees) to the little finger (84.6 ± 12.9 degrees). The little finger MCP joint (26.3 ± 6.2 degrees) showed maximum extension followed by the index finger (25.7 ± 6.8 degrees), middle finger (24.7 ± 6.7 degrees) and ring finger (22.3 ± 7.1 degrees). The middle finger (15.6 ± 8.1 degrees) and ring finger (16.2 ± 8 degrees) had more PIP joint extension when compared to the index (13.7 ± 7.8 degrees) and little finger (13.2 ± 8.4 degrees). The ring finger (8.1 ± 6.8 degrees) and the middle finger (8.4 ± 6.9 degrees) had more DIP joint extension when compared with the index finger (6.0 ± 6.0 degrees) and the little finger (6.8 ± 6.7 degrees). Total active motion (TAM) of the middle finger (315.9 ± 31.0 degrees) was the maximum followed by the index finger (310.2 ± 27.3 degrees), ring finger (308.8 ± 29.1 degrees), and little finger (307.8 ± 25.2 degrees). Gender, body mass index (BMI), mother tongue, geographical location, and occupation were factors that had significant correlation, while no significant differences based on side, hand dominance, and age were noted. Conclusion We have reported normative data of finger ROM and TAM for the index, middle, ring, and little fingers in the Indian population. Finger ROM in the Indian population is highly variable. The observed TAM in the Indian population is higher than what is reported earlier.

Publisher

Georg Thieme Verlag KG

Reference20 articles.

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3