Value of 18F-FDG PET/CT to Identify Occult Infection in Presumed Aseptic Pseudarthrosis after Spinal Fusion: Correlation with Intraoperative Cultures

Author:

El Yaagoubi Yacine1,Lioret Eric2,Thomas Clément2,Loret Jean-Edouard3,Simonneau Adrien3,Michaud-Robert Anne-Victoire1,Philippe Laurent1,Ogielska Maja4,Prunier-Aesch Caroline1

Affiliation:

1. Department of Nuclear Medicine, Vinci Clinic, Tours, France

2. Department of Neurosurgery, Vinci Clinic, Tours, France

3. Department of Neurosurgery, NCT+ Clinic, Tours, France

4. Department of Infectious Diseases, Vinci Clinic, Tours, France

Abstract

Abstract Objective Fluorine-18 fluorodeoxyglucose (18F-FDG) positron emission tomography/computed tomography (PET/CT) has gained attention as an emerging tool in case of suspicion of infection on spine, whether native or instrumented. However, the diagnostic performance of 18F-FDG PET/CT in clinically occult low-grade surgical site infection (SSI) after spinal fusion, an important risk factor for pseudarthrosis, remains unknown. Methods We retrospectively identified all the presumed aseptic patients with pseudarthrosis confirmed by revision surgery who underwent preoperative 18F-FDG PET/CT scans performed between April 2019 and November 2022. These patients were presumed aseptic because they did not have clinical signs or laboratory tests suggestive of SSI, preoperatively. The PET/CT images were analyzed in consensus by two nuclear medicine physicians blinded to the clinical, biological, and imaging information. Visual assessment of increased uptake around cage/intervertebral disk space (and/or hardware) higher than background recorded from the first normal adjacent vertebra was interpreted as positive. Image data were also quantitatively analyzed by the maximum standardized uptake value as an index of 18F-FDG uptake, and the ratio between the uptake around cage/intervertebral disk space (and/or hardware) and background recorded from the first normal adjacent vertebra was calculated. The final diagnosis of infection was based on intraoperative cultures obtained during pseudarthrosis revision surgery. Results Thirty-six presumed aseptic patients with surgically confirmed pseudarthrosis after spinal fusion underwent preoperative 18F-FDG PET/CT scans. Cultures of samples from revisions found that 20 patients (56%) were infected. The most frequent isolated bacterium was Cutibacterium acnes (C. acnes) in 15 patients (75%), followed by coagulase-negative staphylococci (CNS) in 7 patients (33%). Two patients had co-infections involving both C. acnes and CNS. Of the 36 PET/CT studied in this study, 12 scans were true-negative, 10 true-positive, 10 false-negative, and 4 false-positive. This resulted in sensitivity, specificity, positive predictive value, negative predictive value, and diagnostic accuracy of 50%, 75%, 71%, 55%, and 61%, respectively. Conclusion In presumed aseptic pseudarthrosis after spinal fusion, 18F-FDG PET/CT offers good specificity (75%) but low sensitivity (50%) to identify occult SSI. The high prevalence (56%) of SSI, mostly caused by C. acnes (75%), found in our presumed aseptic cohort of patients supports the utility of systematic intraoperative cultures in revision cases for pseudarthrosis.

Publisher

Georg Thieme Verlag KG

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3