Long-Term Safety of a Four-Factor Prothrombin Complex Concentrate (Kcentra®/Beriplex® P/N): An Updated Pharmacovigilance Review

Author:

Milling Truman J.1,Voronov Anna2,Schmidt Dirk S.3,Lindhoff-Last Edelgard4

Affiliation:

1. Department of Clinical Sciences, Tilman J. Fertitta Family College of Medicine, University of Houston, Houston, Texas, United States

2. CSL Behring Australia Pty Ltd, Melbourne, Victoria, Australia

3. CSL Behring GmbH, Marburg, Germany

4. Cardiology Angiology Center Bethanien, CCB Coagulation Research Center, Frankfurt, Germany

Abstract

Introduction Four-factor prothrombin complex concentrate (4F-PCC) is recommended for vitamin K antagonist reversal in patients with major bleeding or in need of surgery. The most important risk associated with the use of 4F-PCC is the occurrence of thromboembolic events (TEEs). In this review, we aim to evaluate the safety profile of a 4F-PCC (Kcentra®/Beriplex® P/N; CSL Behring, Marburg, Germany) by reviewing pharmacovigilance data. Methods A retrospective analysis of postmarketing pharmacovigilance data of Kcentra®/Beriplex® P/N from February 1996 to April 2022 was performed and complemented by a review of clinical studies published between January 2012 and April 2022. Results A total of 2,321,443 standard infusions of Kcentra®/Beriplex® P/N were administered during the evaluation period. Adverse drug reactions (ADRs) were reported in 614 cases (∼1 per 3,781 standard infusions) and 233 of these cases (37.9%) experienced suspected TEEs related to 4F-PCC (∼1 per 9,963 standard infusions); most of these cases had pre-existing or concomitant conditions likely to be significant risk factors for thrombosis. TEE rates were similar when 4F-PCC was used on-label or off-label for direct oral anticoagulant-associated bleeding. Thirty-six cases (5.9%) reported hypersensitivity type reactions (∼1 per 64,485 standard infusions). No confirmed case of viral transmission related to 4F-PCC use was reported. The published literature also revealed a favorable safety profile of 4F-PCC. Conclusion Analysis of postmarketing pharmacovigilance safety reports demonstrated that treatment with 4F-PCC was associated with few ADRs and a low rate of TEEs across multiple indications and settings, thus confirming a positive safety profile of 4F-PCC.

Publisher

Georg Thieme Verlag KG

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3