Comparison of endoscopic ultrasound-guided fine-needle biopsy versus fine-needle aspiration for genomic profiling and DNA yield in pancreatic cancer: a randomized crossover trial

Author:

Kandel Pujan1,Nassar Aziza2,Gomez Victoria1,Raimondo Massimo1,Woodward Timothy A.1,Crook Julia E.3,Fares Natalie S.1,Wallace Michael B.1

Affiliation:

1. Division of Gastroenterology and Hepatology, Mayo Clinic, Jacksonville, Florida, USA

2. Department of Laboratory Medicine & Pathology, Mayo Clinic, Jacksonville, Florida, USA

3. Department of Health Sciences Research, Mayo Clinic, Jacksonville, Florida, USA

Abstract

Abstract Background National guidelines recommend genomic profiling of tumor tissue to guide precision therapy. We compared the specimen adequacy for genomic profiling and yield of DNA between endoscopic ultrasound (EUS)-guided fine-needle biopsy (FNB) and EUS-guided fine-needle aspiration (FNA). Methods In our tandem, randomized controlled trial, consecutive patients undergoing EUS for evaluation of pancreatic masses underwent both conventional EUS-FNA with a 25-gauge needle and paired EUS-FNB (19 or 22-gauge needle), with the order randomized (EUS-FNA first followed by EUS-FNB, or vice versa). A minimum of one pass with each needle was obtained for histology. Second and third passes were performed to collect DNA. Specimens were evaluated by a cytopathologist blinded to the needle type. Specimen adequacy for genomic profiling was calculated based on FoundationOne clinical diagnostic (CDx) adequacy requirements. We compared the adequacy for genomic profiling DNA (quantity) and histology yields with both needles. Results Analysis included 50 patients (25 men; mean age 68 [standard deviation (SD) 13] years), with a mean lesion size of 38 (SD 17) mm; 37 lesions (74 %) were pancreatic ductal adenocarcinoma (PDAC). The mean DNA concentrations in PDAC by FNB and FNA needles were 5.930 (SD 0.881) µg/mL vs. 3.365 (SD 0.788) µg/mL, respectively (P = 0.01). The median standardized histology score per pass with EUS-FNB was 5 (sufficient for histology) and for EUS-FNA was 2 (enough for cytology). Specimen adequacy for genomic profiling and yield of DNA was significantly higher with FNB than with FNA needles. Conclusions In this study, adequacy for genomic profiling, DNA, and histology yield were considerably superior using an EUS-FNB needle compared with an EUS-FNA needle.

Publisher

Georg Thieme Verlag KG

Subject

Gastroenterology

Reference28 articles.

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3