A Novel Radiological Classification System of the Proximal Humerus

Author:

Sangaletti Rudy12,Abuljadail Salahulddin32,Akkaya Mustafa24,Zanna Luigi2,Gehrke Thorsten2,Citak Mustafa2ORCID

Affiliation:

1. Sezione Di Chirurgia Protesica Ad Indirizzo Robotico - Unità Di Traumatologia Dello Sport, Poliambulanza Foundation Hospital Institute, Brescia, Italy

2. Department of Orthopaedic Surgery, HELIOS ENDO-Klinik Hamburg, Hamburg, Germany

3. Orthopaedic Surgery, King Faisal University, Hofuf, Saudi Arabia

4. Department of Orthopaedics and Traumatology, Ankara Yildirim Beyazit Universitesi Tip Fakultesi, Ankara, Turkey

Abstract

AbstractDifferent anatomical variants have been reported for the proximal and distal femur. Given this context, the goal of our study was to answer the following question: Can we also identify different anatomical variants of the proximal humerus?Two hundred anteroposterior (AP) radiographs of the proximal humerus with an equal gender distribution and equal laterality per gender were reviewed. The metaphyseal diameter of the proximal humerus at the level of the anatomical neck (X) and the intramedullary diameter at 10 cm from the apex of the greater tuberosity (Y) were measured. A new ratio was established, based on both measurements (Y/X). Radiographs showed different anatomical variants: type A: Y/X < 0.3, type B: Y/X = 0.3–0.4, type C: Y/X > 0.4. Two observers reviewed the AP radiographs independently and blindly in 2 different sessions.Three different anatomical groups (A, B and C) were identified based on the 25th and 75th percentiles. A higher percentage of type C was observed among females and a higher percentage of type A among males. A high inter-observer reliability was noted, with a Cronbach’s alpha of 0.97 (ICC 0.96–0.98). The intra-observer reliability for observer 1 had a Cronbach’s alpha of 0.98.A novel radiological classification of the proximal humerus has been established based on 3 different anatomical types (A, B and C). Further studies are needed to establish whether the novel classification system can be used as an indicator for aseptic loosening of cemented or cementless total shoulder arthroplasty.

Publisher

Georg Thieme Verlag KG

Subject

Orthopedics and Sports Medicine,Surgery

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3