Mechanical Evaluation of Bone–Patellar Tendon–Bone Graft Fixation to the Tibia in ACL Reconstruction: Bone Plug Tensioning and Fixation System versus Interference Screw

Author:

Iuchi Ryo1,Shino Konsei2,Mae Tatsuo2,Yamakawa Satoshi3,Nakata Ken3

Affiliation:

1. Department of Orthopaedic Sports Medicine, Kansai Rosai Hospital, Amagasaki, Japan

2. Sports Orthopedic Center, Yukioka Hospital, Osaka, Japan

3. Department of Health and Sport Sciences, Graduate School of Medicine, Osaka University, Osaka, Japan

Abstract

AbstractThis study aimed to evaluate the mechanical properties of bone plug fixation to the tibia with a novel device, the Bone plug Tensioning and Fixation (BTF) system.Forty bone–tendon–bone grafts consisting of the whole patella–patellar tendon–tibial bone plug of 10-mm width and tibiae from the porcine were prepared. After creating a 10-mm tibial tunnel, the tibial bone plug was fixed to the tibia with the BTF system or the interference screw (IFS) to prepare a test specimen of the patella–patellar tendon–tibial bone plug fixed to the tibia. For the graft tension controllability study, a predetermined initial tension of 9.8 or 19.6 N was applied and maintained for 5 minutes. Then the bone plug was fixed to the tibia with the BTF system or IFS in 10 specimens, monitoring the residual tension for an additional 5 minutes. Then, a cyclic loading test and a tension-to-failure test were performed.The mean difference between the residual tension and the predetermined tension was significantly smaller in BTF fixation (9.8 N → 10.6 ± 2.2 N; 19.6 N → 18.9 ± 2.1 N) than in IFS fixation (9.8 N → 23.4 ± 7.4 N; 19.6 N → 28.9 ± 11.5 N). The mean displacement of the bone plug after cyclic loading was significantly less in the BTF group (1.2 ± 0.6 mm) than in the IFS group (2.2 ± 1.0 mm; p < 0.01). Stiffness was significantly greater in the BTF group (504.6 ± 148.8 N/mm) than in the IFS group (294.7 ± 96.7 N/mm; p < 0.01), whereas the maximum failure loads in the two groups did not differ significantly (724.2 ± 180.3 N in the BTF and 634.8 ± 159.4 N in the IFS groups).BTF system better performed in graft tension controllability than IFS did. BTF fixation was superior to IFS fixation in the displacement of the bone plug during the cyclic loading test and in stiffness in the tension-to-failure test.

Publisher

Georg Thieme Verlag KG

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3