Semi-automated Analysis of Ventilation-Perfusion Single-Photon Emission Tomography in the Diagnosis of Pulmonary Embolism – Does it add extra value?

Author:

Kurth Jens1ORCID,Uhländer Johannes1,Aladwan Hamzeh12,Göhrendt Anna1,Baier Henriette1,Heuschkel Martin1,Schümichen Carl3,Krause Bernd Joachim1,Schwarzenböck Sarah Marie1

Affiliation:

1. Universitätsmedizin Rostock, Klinik und Poliklinik für Nuklearmedizin, Rostock, Germany

2. Jordanian Royal Medical Services, King Hussein Medical Center, Amman, Jordan

3. Praxis für Nuklearmedizin Rostock, Rostock, Germany

Abstract

Abstract Aim Diagnosis of pulmonary embolism using V/P-SPECT may include the application of advanced image-processing techniques to identify V/P-mismatches. Aim of this study was to evaluate the benefit in clinical decision making in the diagnosis of pulmonary embolism.by whether adding to conventional reading a software that automatically calculates and visualizes the ventilation/perfusion-quotient pixel by pixel. Methods 63 consecutive patients with a clinical suspicion of PE who underwent V/P-SPECT were included in this retrospective study. Images were randomly ordered both for standard as well as for software-assisted reading using V/P-quotients. Studies were read independently by 2 experienced and 2 inexperienced raters. Diagnostic performance and observer agreement of all readers and both reading methods were determined. Results Expert observers consistently achieved a high diagnostic accuracy both in conventional as well as in software-assisted reporting (sensitivity: 0.94 vs. 0.94, specificity: 0.96 vs. 0.97, LR+: 17.32 vs. 28.86, LR– stayed constant at 0.06). For inexperienced readers, diagnostic performance improved: sensitivity raised from 0.74 to 0.85 and specificity from 0.86 to 0.95, LR+ raised from 5.20 to 15.69, LR– decreased from 0.31 to 0.16. Inter-rater reliability (Fleiss’ κ) improved from 0.63 to 0.86 by using V/P quotient. Conclusion Benefit from a software-tool that calculates V/P-ratio automatically is only small when used by experienced physicians If inexperienced readers use the software, the diagnostic accuracy increases. Images generated by automated calculation of V/P-mismatches are easy to read and their use might help to standardize and objectify interpretation of V/P-SPECT in the diagnosis of PE.

Publisher

Georg Thieme Verlag KG

Subject

Radiology, Nuclear Medicine and imaging,General Medicine

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3