The feasibility and safety of disposable endoscope vs. conventional endoscope for upper gastrointestinal tract examination: a multicenter, randomized, parallel, non-inferiority trial

Author:

Li De-feng1,Shi Rui-yue1,Tian Yan-hui1,Xu Zheng-lei1,Zhou Ying-sheng2,Sun Xian-jiu2,Cai Jin-wei2,Fang Yuan-yuan2,Peng Huan2,Wang Jia-min2,Dong Tao3,Cai Yong-de3,Yao Jun1,wang Li-sheng1

Affiliation:

1. Department of Gastroenterology, Shenzhen People's Hospital (The Second Clinical Medical College, Jinan University, The First Affiliated Hospital, Southern University of Science and Technology),

2. Department of Gastroenterology, University of Chinese Academy of Sciences Affiliated Shenzhen Hospital,

3. Shenzhen Pengrui Intelligent Image Co., Ltd,

Abstract

Abstract Background A disposable upper gastrointestinal endoscope can effectively decrease infectious outbreaks associated with endoscope reuse. In the present study, we aimed to evaluate the feasibility and safety of a disposable endoscope for upper gastrointestinal examination. Methods In a prospective, randomized trial, 144 upper endoscopic procedures were allocated to either the disposable endoscope group or the conventional endoscope group. The primary outcomes were rates of excellent and good image qualities and maneuverability satisfaction. The second outcome included procedure duration, endoscopic diagnosis, and adverse events. Results A total of 144 subjects were enrolled in the present analysis and prospectively randomized to 2 study groups. Finally, 70 and 69 subjects were enrolled in the novel disposable endoscope group and the conventional endoscope group, respectively, due to the schedule cancellation of 5 subjects. The baseline characteristics of the patients were similar in both groups. The excellent and good image quality rates and maneuverability satisfaction of the novel disposable endoscope were not inferior to the conventional endoscope (p = 0.99 and p = 0.99, respectively). Moreover, no significant between-group difference was observed in the endoscopic results and adverse events (p = 0.30 and p = 1, respectively). However, the procedure duration in the novel disposable endoscope was longer compared with the conventional endoscope (8.40 ± 4.28 min vs. 5.12 ± 2.65 min, p < 0.001). Conclusions The novel disposable endoscope was as safe, effective, and maneuverable as a conventional endoscope. However, the novel disposable endoscope was associated with a longer procedure duration.

Funder

Natural Science Foundation of Guangdong Province

Technical Research and Development Project of Shenzhen

Shenzhen Health Planning Commission

National Natural Science Foundation of China

Three Engineering Training Funds in Shenzhen

Publisher

Georg Thieme Verlag KG

Subject

Gastroenterology