Reduction of Radiation Exposure in Adrenal Vein Sampling: Impact of the Rapid Cortisol Assay

Author:

Augustin Anne Marie1,Dalla Torre Giulia1,Fuss Carmina Teresa2,Fassnacht Martin2,Bley Thorsten Alexander1,Kickuth Ralph1

Affiliation:

1. Department of Diagnostic and Interventional Radiology, University Hospital Würzburg, Würzburg, Germany

2. Department of Internal Medicine I, Division of Endocrinology and Diabetes, University Hospital Würzburg, Würzburg, Germany

Abstract

Purpose To determine radiation exposure associated with adrenal vein sampling and its reduction by implementing the rapid cortisol assay and modification of the sampling protocol. Materials and Methods A single-center retrospective study of adrenal vein sampling performed between August 2009 and March 2020 revealed data from 151 procedures. Three subgroups were determined. In group I, a sampling protocol including sampling from the renal veins without the rapid cortisol assay was applied. In group II, blood was sampled using the same protocol but applying the rapid cortisol assay. In group III, a modified sampling protocol was used, in which the additional sampling from the renal veins was dispensed with, while the rapid cortisol assay was retained. Primary endpoints were radiation exposure parameters with dose area product, fluoroscopy time, and effective dose. As secondary endpoints, procedural data including technical success, lateralization, the correlation between patient BMI and radiation exposure, and concordance of lateralization with cross-sectional imaging were investigated. Furthermore, the correlation of aldosterone-cortisol ratios between the adrenal and ipsilateral renal vein was calculated to assess the benefit of sampling from the renal veins. Results For all procedures performed in the study collective, the median dose area product was 60.01 Gy*cm2 (5.71–789.31), the median fluoroscopy time was 14.90 min (3.27–80.90), and the calculated median effective dose was 12.60 mSv (1.20–165.76). Significant differences in radiation exposure parameters between the study subgroups could be revealed. Dose area product resulted in reductions of 57.94 % after implementation of the rapid cortisol assay and a further 40.44 % after revision of the sampling protocol. Fluoroscopy time was reduced by 40.48 % after integration of the rapid cortisol assay and a further 40.47 % after protocol refinement. Radiation doses were increased in cases of resampling (dose area product 51.31 vs. 118.11 Gy*cm2, fluoroscopy time of 12.48 vs. 28.70 min). A strong correlation between patient BMI and procedural dose area product could be found. After the introduction of the rapid cortisol assay, successive improvement of the technical success rate could be found (33.33 % in group I, 90.22 % in group II and 92.11 % in group III). The correlation of aldosterone-cortisol ratios between adrenal and renal veins was poor. Conclusion The introduction of the rapid cortisol assay significantly decreased the radiation exposure and increased the technical success rate. Renal vein sampling did not provide further benefit in the evaluation of primary aldosteronism subtype and its omission resulted in a further reduction of radiation dose. Key Points: Citation Format

Publisher

Georg Thieme Verlag KG

Subject

Radiology Nuclear Medicine and imaging

Cited by 7 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3