Radiation exposure during modern therapeutic endoscopic ultrasound procedures and standard alternatives

Author:

Vanella Giuseppe1,Dell’Anna Giuseppe1,Loria Alessandro2,Petrone Maria Chiara1,Del Vecchio Antonella2,Arcidiacono Paolo Giorgio1

Affiliation:

1. Pancreatobiliary endoscopy and Endosonography Division, Pancreas Translational and Clinical Research Centre, IRCSS San Raffaele Scientific Institute, Milan, Italy

2. Medical Physics Department, IRCCS San Raffaele Scientific Institute, Milan, Italy

Abstract

Abstract Background and study aims Therapeutic EUS (t-EUS) is increasingly being adopted in clinical practice in tertiary referral centers; however, little is known about radiation exposure (RE) metrics and diagnostic reference limits for it. Methods Kerma-area product (KAP [Gy·cm2]), Air Kerma and fluoroscopy time were retrospectively evaluated for all consecutive t-EUS procedures performed in San Raffaele Institute between 2019 and 2021. For EUS-guided choledochoduodenostomies (EUS-CDS) and gastroenterostomies (EUS-GE), an equal number of endoscopic retrograde cholangiopancreatographies (ERCPs) plus metal stenting and duodenal stents were included respectively for comparison. Results Data from 141 t-EUS procedures were retrieved (49 % pancreatic cancer, 38 % peripancreatic fluid collections). EUS-CDS (N = 44) were mainly performed fluoroless, while ERCPs required a significantly higher RE (KAP = 25 [17–55], P < 0.0001). Fluid collection drainage (EUS-FCD) with lumen apposing metal stents (LAMS, N = 26) were performed fluoroless, while EUS-FCD with double-pigtail plastic stents (DPPS, N = 28) required higher RE (KAP = 23 [13–45]). EUS-guided gallbladder drainage (EUS-GBD, N = 6) required scarce RE (KAP = 9 [3–21]) for coaxial DPPS placement. EUS-GE (N = 27) required higher RE than duodenal stenting (KAP = 44 [28–88] versus 29 [19–46], P = 0.03). EUS-guided hepaticogastrostomies (EUS-HGS, N = 10) had the highest RE among t-EUS procedures (KAP = 81 [49–123]). Procedure complexity or intervening complications were evaluated and resulted in higher RE within each procedure. Conclusions t-EUS procedures have different RE (P < 0.000001). EUS-CDS, EUS-GBD, and EUS-FCD with LAMS can be performed with no-to-mild radioscopy, unlike standard alternatives. However, radioscopy remains essential in case of technical difficulties or complications. EUS-GE and EUS-HGS involve a high RE. Endoscopists involved in t-EUS might experience RE higher than category standards, which indicates a need for increased awareness and personalized preventive measures.

Publisher

Georg Thieme Verlag KG

Subject

Gastroenterology,Medicine (miscellaneous)

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3