Computer Patient-Specific 3D Modeling and Custom-Made Guides for Revision ACL Surgery

Author:

Del Prete Armando1,Franco Piero1,Innocenti Matteo1,Matassi Fabrizio1,Leggieri Filippo1ORCID,Sagliocco Rosario Jr1,Civinini Roberto1

Affiliation:

1. Department of Orthopaedic Surgery, University of Florence, Florence, Italy

Abstract

AbstractRevision anterior cruciate ligament reconstruction (ACLR) is a challenging surgery occurring in 3 to 24% of primary reconstructions. A meticulous planning to study the precise size and location of both femoral and tibial bone tunnels is mandatory. The aim of the study was to evaluate the intra- and interoperator differences in the decision-making process between experienced surgeons after they were asked to make preoperative planning for ACL revision reconstruction with the use of both the computed tomography (CT) scan and a three-dimensional (3D)-printed model of the knee. Data collected from 23 consecutive patients undergoing revision of ACLR for graft failure at a single institute between September 2018 and February 2020 were prospectively reviewed. The double-blinded collected data were presented to three board-certificate attending surgeons. Surgeons were asked to decide whether to perform one-stage or two-stage revision ACLR based on the evaluation of the CT scan images and the 3D-printed custom-made models at two different rounds, T0 and T1, respectively, 7 days apart one from the other. Interoperator consensus following technical mistake was 52% at T0 and 56% at T1 using the CT scans, meanwhile concordance was 95% at T0 and 94% at T1 using the 3D models. Concordance between surgeons following new knee injury was 66% at T0 and 70% at T1 using CT scans, while concordance was 96% both at T0 and T1 using 3D models. Intraoperative variability using 3D models was extremely low: concordance at T0 and T1 was 98%. McNemar test showed a statistical significance in the use of 3D model for preoperative planning (p < 0.005). 3D-printed model reliability resulted to be higher compared with CT as intraoperator surgery technique selection was not modified throughout time from T0 to T1 (p < 0.005). The use of 3D-printed models had the most impact when evaluating femoral and tibial tunnels, resulting to be a useful instrument during preoperative planning of revision ACLR between attending surgeons with medium-high workflow.

Publisher

Georg Thieme Verlag KG

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3