Suture or Stapling Are Superior in Comparison to Bipolar Sealing for Closing the Bronchi

Author:

Waubke Katharina1,Pehl Anika2,Steinfeldt Thorsten3,Bartsch Detlef1,Kirschbaum Andreas1

Affiliation:

1. Department of Surgery, University Hospital Marburg, Marburg, Germany

2. Department of Pathology, University Hospital Marburg, Marburg, Germany

3. Department of Anaesthesia and Intensive Care, University Hospital Marburg, Marburg, Germany

Abstract

Background Every anatomical lung resection requires the airtight closure of at least one bronchus. In current clinical practice, these bronchi are sealed with sutures or staplers. This study investigated in an ex vivo pig model whether a new bipolar sealing device MARSEAL (KLS Martin, Tuttlingen, Germany) could be an alternative for this purpose. Methods Complete bronchial trees were prepared free from pig heart–lung blocks that were removed at a slaughterhouse. These preparations were taken to the laboratory, and main, lobar, and segmental bronchi were closed using sutures, staples, or bipolar sealing. Each trachea was then intubated and connected to a ventilating device. The initial airtight closure of the bronchus was first tested with lung-protective ventilation. After 15 minutes of ventilation, the inspiratory ventilation pressure was slowly increased and the burst pressure (in mbar) was recorded. Each group included 12 bronchus closures. Group mean burst pressures were compared using a nonparametric test (Mann–Whitney U test). The significance level was p < 0.05. Results The main bronchi closed both stapler magazines or sutures were all initially airtight during ventilation. The mean burst pressure was 60 ± 0 mbar for staplers and 57.92 ± 5.8 mbar for sutures. In contrast, 50% of main bronchi sealed with MARSEAL devices (5 or 10 mm) leaked air from the beginning. This was also noted in all lobar bronchi sealed with the MARSEAL 5-mm device and 80% of those sealed with the MARSEAL 10-mm device. The mean burst pressure of initially airtight lobar bronchi was 12.7 ± 7.25 mbar. In contrast, all segmental bronchi (mean width: 1.6 cm) were airtight when ventilated. Mean burst pressure was 14.64 ± 9.1 mbar with the MARSEAL 5-mm device and 29.64 ± 21.3 mbar with the MARSEAL 10-mm device. Histological investigation of the preparations (with hematoxylin and eosin staining) showed intact cartilaginous structures that were largely unaffected by bipolar coagulation. The airtight sealing of the segmental bronchi resulted from fusion of the peribronchial tissue and not the cartilage. Conclusion Bipolar sealing is an inappropriate tool for the closure of the bronchi in comparison to suture or stapling.

Publisher

Georg Thieme Verlag KG

Subject

Cardiology and Cardiovascular Medicine,Pulmonary and Respiratory Medicine,Surgery

Cited by 3 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3