An Advanced Knee Simulator Model Can Reproducibly Be Used for Ligament Balancing Training during Total Knee Arthroplasty

Author:

Logan Scott1,Sequeira Sean B.2,Jerabek Seth A.3,Malkani Arthur L.4,Mahoney Ormond M.5,Crutcher James P.6,Mont Michael A.7,Faizan Ahmad1

Affiliation:

1. Department of Marketing and Engineering, Stryker, Mahwah, New Jersey

2. Department of Orthopedic Surgery, MedStar Union Memorial Hospital, Baltimore, Maryland

3. Department of Orthopedic Surgery, Hospital for Special Surgery, New York City, New York

4. Department of Orthopaedic Surgery, University of Louisville, Louisville, Kentucky

5. Athens Orthopaedic Clinic, Athens, Georgia

6. Orthopedic Physician Associates, Seattle, Washington

7. Department of Orthopaedic Surgery, Rubin Institute for Advanced Orthopedics, Sinai Hospital of Baltimore, Baltimore, Maryland

Abstract

AbstractA critical and difficult aspect of total knee arthroplasty (TKA) is ligamentous balancing for which cadavers and models have played a large role in the education and training of new arthroplasty surgeons, although they both have several shortcomings including cost, scarcity, and dissimilarity to in vivo ligament properties. An advanced knee simulator (AKS) model based on computed tomography (CT) scans was developed in the setting of these challenges with cadavers and previous models. In this study, we compared the ligament balancing between AKS and human cadaveric knees to assess the validity of using the AKS for ligament balancing training during TKA. A CT scan of a TKA patient with varus deformity was used to design the AKS model with modular components, using three-dimensional printing. Three fellowship-trained arthroplasty surgeons used technology-assisted TKA procedure to plan and balance three cadaver knees and the AKS model. Medial and lateral laxity data were captured using manual varus and valgus stress assessments for cadavers and the model in an extension pose (10 degrees of flexion from terminal extension) and between 90 and 95 degrees for flexion. After preresection assessments, surgeons planned a balanced cruciate-retaining TKA. Following bony cuts and trialing, extension and flexion ligament laxity values were recorded in a similar manner. Descriptive statistics and Student's t-tests were performed to compare the cadavers and model with a p-value set at 0.05. Preresection medial/lateral laxity data for both extension and flexion were plotted and showed that the highest standard deviation (SD) for the cadavers was 0.67 mm, whereas the highest SD for the AKS was 1.25 mm. A similar plot for trialing demonstrated that the highest SD for the cadavers was 0.6 mm, whereas the highest SD for the AKS was 0.61 mm. The AKS trialing data were highly reproducible when compared with cadaveric data, demonstrating the value of the AKS model as a tool to teach ligament balancing for TKA and for future research endeavors.

Publisher

Georg Thieme Verlag KG

Reference16 articles.

1. The MAKO robotic-arm knee arthroplasty system;M Roche;Arch Orthop Trauma Surg,2021

2. Relative clinical outcomes comparing manual and robotic-assisted total knee arthroplasty at minimum 1-year follow-up;J Mitchell;HSS J,2021

3. Robotic-arm assisted technology's impact on knee arthroplasty and associated healthcare costs;D J Kolessar;J Health Econ Outcomes Res,2022

4. Clinical results and patient-reported outcomes following robotic-assisted primary total knee arthroplasty: a multicentre study;P Y Joo;Bone Jt Open,2022

5. Clinical outcomes after computed tomography-based total knee arthroplasty: a surgeon's first 1,000 cases;R C Marchand;Surg Technol Int,2022

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3