Abstract Objective To evaluate the corneal topographic parameter values measured with the Pentacam Scheimpflug system in patients with multiple sclerosis (MS). Methods A total of 108 eyes of 62 MS patients were studied. In addition to a complete examination of anterior and posterior segments, all patients were scanned using the Pentacam Scheimpflug camera. The diagnosis of MS was made according to the McDonald criteria. All MS patients were clinically assessed using the Multiple Sclerosis Severity Score (MSSS). Results The mean age was 38.89 ± 10.18 years (36.16 – 41.30) for MS patients and 40.94 ± 9.44 years (38.49 – 43.11) for the controls (p = 0.26). Only central corneal thickness (CCT) and corneal volume (CV) values were significantly lower in MS patients (p < 0.001). The other corneal parameters were not significantly different between the study eyes and control eyes (p > 0.05 for all). Pachymetric measurements at the corneal apex were 525.69 ± 29.35 (518.29 – 533.67) µm for the study eyes versus 563.13 ± 23.70 (562.13 – 576.36) µm for the control eyes. CV were 59.22 ± 4.11(58.18 – 60.20) mm3 for the study eyes versus 62.78 ± 3.09 (62.38 – 64.00) mm3 for the control eyes. Conclusion This is the first study that has reported lower CCT and CV measurements in MS patients than healthy subjects of a similar age. These results should be supported by further studies.

Publisher

Georg Thieme Verlag KG

Subject

Ophthalmology

Reference30 articles.

1. Multiple sclerosis;A Compston;Lancet,2008

2. Axonal damage in acute multiple sclerosis lesions;B Ferguson;Brain,1997

3. Clinico-pathological evidence that axonal loss underlies disability in progressive multiple sclerosis;E C Tallantyre;Mult Scler,2010

4. Multiple sclerosis and the visual system;D A Jacobs;Ophthalmol Clin North Am,2004

5. An investigation of the retinal nerve fibre layer in progressive multiple sclerosis using optical coherence tomography;A P Henderson;Brain,2008

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3