Lung Ultrasound as a Promising Diagnostic Tool for Primary Graft Dysfunction after Lung Transplantation

Author:

Schroeder Ines1,Scharf Christina1,Schneider Julia1,Weggesser Patricia1,Hübner Lucas1,Kneidinger Nikolaus2,Michel Sebastian3,Schneider Christian4,Clevert Dirk-Andre5,Sabel Bastian5,Irlbeck Michael1,Scheiermann Patrick1

Affiliation:

1. Department of Anesthesiology, University Hospital, LMU Munich, Munich, Germany

2. Department of Internal Medicine V, University Hospital, LMU Munich, Munich, Germany

3. Department of Cardiac Surgery, University Hospital, LMU Munich, Munich, Germany

4. Department of Thoracic Surgery, University Hospital, LMU Munich, Munich, Germany

5. Department of Radiology, University Hospital, LMU Munich, Munich, Germany

Abstract

Abstract Purpose The aim of the study was to evaluate whether the quantification of B-lines via lung ultrasound after lung transplantation is feasible and correlates with the diagnosis of primary graft dysfunction. Methods Following lung transplantation, patients underwent daily lung ultrasound on postoperative days 1–3. B-lines were quantified by an ultrasound score based on the number of single and confluent B-lines per intercostal space, using a four-region protocol. The ultrasound score was correlated with the diagnosis of primary graft dysfunction. Furthermore, correlation analyses and receiver operating characteristics analyses taking into account ultrasound score, chest radiographs, and PaO2/FiO2 ratio were performed. Results A total of 32 patients (91 ultrasound measurements) were included, whereby 10 were diagnosed with primary graft dysfunction. The median B-line score was 5 [IQR: 4, 8]. There was a significant correlation between B-line score and the diagnosis of primary graft dysfunction (r = 0.59, p < 0.001). A significant correlation could also be seen between chest X-rays and primary graft dysfunction (r = 0.34, p = 0.008), but the B-line score showed superiority over chest X-rays with respect to diagnosing primary graft dysfunction in the receiver operating characteristics curves with an area under the curve value of 0.921 versus 0.708. There was a significant negative correlation between B-line score and PaO2/FiO2 ratio (r = –0.41, p < 0.001), but not between chest X-rays and PaO2/FiO2 ratio (r = –0.14, p = 0.279). Conclusion The appearance of B-lines correlated well with primary graft dysfunction and outperformed chest radiographs.

Publisher

Georg Thieme Verlag KG

Subject

Radiology, Nuclear Medicine and imaging

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3