A Reliable Method for the Monitoring of Buried Free Flaps Using Near-Infrared Spectroscopy

Author:

Sweitzer Keith1,Carruthers Katherine2,Tiwari Pankaj3,Kocak Ergun3

Affiliation:

1. Division of Plastic Surgery, Strong Memorial Hospital, University of Rochester, Rochester, New York

2. Division of Plastic and Reconstructive Surgery, West Virginia University Health Sciences Center, Morgantown, West Virginia

3. Midwest Breast & Aesthetic Surgery, Gahanna, Ohio

Abstract

Abstract Background In recent years, there has been a shift toward nipple-sparing mastectomy (NSM) techniques which often negates the need for reconstruction with exposed cutaneous donor flap tissues. Although techniques for the monitoring of buried flaps have been proposed, none have been able to provide the benefits that come with cutaneous monitoring via near-infrared spectroscopy (NIRS). Therefore, we herein propose a novel method for monitoring deepithelialized flap tissues deep to the mastectomy flaps using NIRS technology. Methods An NSM with free flap reconstruction was performed. The flap was designed with a skin island for placement of a cutaneous NIRS probe. Next, a silicone NIRS probe was placed on a deepithelialized portion of the flap under the mastectomy flap. The readings from this tunneled device were then compared to the control measurements obtained from the cutaneous NIRS monitor. This procedure was performed on three consecutive patients. The changes in StO2 recorded from both devices were compared using a paired, two-tailed Student's t-test. Results During flap monitoring, there were no issues with probe dislodgement and signal quality averaged greater than 90. Furthermore, probe removal was easily accomplished at bedside. There was no harm to the mastectomy skin flaps by affixing the probe and the pocket which contained the probe quickly closed down after removal. Using the Student's t-test, a p-value of 0.995 was calculated indicating no statistically significant difference between the StO2 readings from the cutaneous and the tunneled probes. Conclusion By using this novel method, NIRS technology can reliably be applied to the monitoring of buried free flap tissues. The proposed technique could be applied to a variety of flaps beyond the realm of breast reconstruction and may prove to be particularly useful in the setting of head and neck reconstruction. The results of this study suggest that high quality postoperative flap monitoring is possible without compromising the aesthetic result.

Publisher

Georg Thieme Verlag KG

Subject

General Medicine

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

1. NIRO200NX: Reliable Monitoring System for Buried Deep Inferior Epigastric Perforator Flap;Plastic and Reconstructive Surgery - Global Open;2024-08

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3