Four-Corner Arthrodesis with a Dorsal Locking PEEK Plate: A Retrospective Case Series

Author:

Hayes Emmitt1ORCID,Leswick David A.2ORCID,Obaid Haron2ORCID,Sauder David A.34

Affiliation:

1. Division of Orthopedic Surgery, University of Saskatchewan College of Medicine, Saskatoon, Saskatchewan, Canada

2. Department of Medical Imaging, Saskatchewan Health Authority, University of Saskatchewan, Saskatoon, Saskatchewan, Canada

3. Division of Orthopedic Surgery, Royal University Hospital, University of Saskatchewan College of Medicine, Saskatoon, Saskatchewan, Canada

4. Saskatoon Orthopedic and Sports Medicine Center, Saskatoon, Saskatchewan, Canada

Abstract

Abstract Background Four-corner arthrodesis (4CA) can be performed with a variety of methods. To our knowledge, fewer than 125 cases of 4CA with a locking polyether ether ketone (PEEK) plate have been reported, necessitating further study. Purpose The purpose of this study was to evaluate the radiographic union rate and clinical outcomes in a series of patients who received 4CA with a locking PEEK plate. Methods We re-examined 39 wrists in 37 patients at a mean follow-up of 50 months (median: 52 months, range: 6–128). Patients completed the Quick Disabilities of the Arm, Shoulder, and Hand (QuickDASH), Patient-Rated Wrist Evaluation (PRWE), and participated in measurements of grip strength and range of motion. Anteroposterior, lateral, and oblique radiographs of the operative wrist were examined for union, screw breakage and/or loosening, and lunate change. Results The mean QuickDASH score was 24.4 and the mean PRWE score was 26.5. Mean grip strength was 29.2 kg or 84% of the nonoperative hand. Mean flexion, extension, radial deviation, and ulnar deviation were : 37.2, 28.9, 14.1, and 17.4 degrees, respectively. Eighty-seven percent of wrists achieved union; 8% had nonunion; and5% had indeterminate union. There were seven cases of screw breakage and seven cases of screw loosening (as defined by lucency or bony resorption surrounding screws). Twenty-three percent of wrists required reoperation (four total wrist arthrodesis and five reoperations for other reasons). Conclusion 4CA with a locking PEEK plate has clinical and radiographic outcomes similar to other methods. We observed a high rate of hardware complications. It is unclear whether this implant offers a clear advantage over other methods of fixation used in 4CA. Type of Study/Level of Evidence Level IV, therapeutic study.

Publisher

Georg Thieme Verlag KG

Subject

Orthopedics and Sports Medicine,Surgery

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3