AbstractTemplating prior to total hip arthroplasty is a widely adopted practice that aims to improve operative efficiency and reduce clinical outliers. Predicting implant size before total knee arthroplasty (TKA), although less common, could increase operating room efficiency by reducing necessary equipment needed for the procedure. This study compared templating accuracy in TKA using two-dimensional (2D) digital radiographs to a novel imaging technology that generates a three-dimensional (3D) model from these 2D radiographs. Two hundred and two robotic-assisted primary TKA surgical cases using Persona Knee System (Zimmer Biomet, Warsaw, IN) were retrospectively analyzed. For all cases, 3D templating was completed preoperatively using a novel radiographic image acquisition protocol. Using the same radiographs, the knee was templated using a 2D digital templating program. All surgeons were blinded to the final implant sizes, and all templating was done independently. The accuracy of predictions within ± 1 from the final implant size was determined for the femoral and tibial components. The accuracy (within 1 size) of tibial size predictions was comparable between attending surgeons and residents (87 vs. 82%, p = 0.08), but attending surgeons more accurately predicted the femoral size (77 vs. 60%, p < 0.05). The 2D to 3D imaging technology more accurately predicted both tibial and femoral sizes compared with the attending surgeons (99.5 vs. 87%, p < 0.05; 84% vs. 77%, p < 0.05). However, the imaging technology, attending surgeons, and residents were all more likely to overestimate femur size (p < 0.05). Moreover, the 3D imaging technology predicted the exact tibial component size in 93.1% of cases, which was significantly greater compared with residents (40%, p < 0.01) and attending surgeons (53%, p < 0.01). The 2D to 3D imaging technology more accurately predicted tibial and femoral component sizes compared with 2D digital templating done by surgeons. All templating predictions were more accurate for the tibial implant size than for the femoral size. The increased accuracy of implant size predictions from this 3D templating technology has the potential to improve intraoperative efficiency and minimize costs and surgical time.
Subject
Orthopedics and Sports Medicine,Surgery
Reference28 articles.
1. Press-fit condylar design total knee arthroplasty. Fourteen to seventeen-year follow-up;D J Rodricks;J Bone Joint Surg Am,2007
2. Effect of training level on accuracy of digital templating in primary total hip and knee arthroplasty;A R Hsu;Orthopedics,2012
3. Total knee and hip prosthesis: variables associated with costs [in Spanish];C Herrera-Espiñeira;Cir Cir,2013
4. Digital templating in primary total hip and knee arthroplasty;B Levine;Orthopedics,2010
5. Acetate templating on digital images is more accurate than computer-based templating for total hip arthroplasty;R Petretta;Clin Orthop Relat Res,2015
Cited by
7 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献