Rapid Detection of Apixaban by a ROTEM-Based Approach and Reversibility with Andexanet Alfa or DOAC-Stop

Author:

Taune Viktor1,Skeppholm Mika1,Ågren Anna1,Wikman Agneta2,Hillarp Andreas34,Wallén Håkan1

Affiliation:

1. Department of Clinical Sciences, Danderyd Hospital, Division of Cardiovascular Medicine, Karolinska Institutet, Stockholm, Sweden

2. Division of Clinical Immunology and Transfusion Medicine, Department of Laboratory Medicine, Karolinska University Hospital, Stockholm, Sweden; Department of Laboratory Medicine, Karolinska Institutet, Stockholm, Sweden

3. Department of Translational Medicine, Clinical Chemistry Malmö, Lund University, Malmö, Sweden

4. Department of Medical Biochemistry, Oslo University Hospital, Oslo, Norway

Abstract

Abstract Background A rapid test to detect apixaban treatment would be useful in acute situations such as major bleeding, urgent surgery, or in acute thrombosis. Objective This article aims to study if the viscoelastic test rotational thromboelastometry (ROTEM) can rapidly detect apixaban in whole blood using modified triggers based on factor Xa (FXa) or Russell viper venom (RVV). Method ROTEM clotting time (CT) was measured in samples from 40 patients on apixaban treatment, and in vitro in samples spiked with apixaban (20–500 ng/mL). Commercially available trigger Ex-tem was compared with modified triggers based on FXa or RVV. Reversibility of apixaban in the samples was studied; CT was measured with and without addition of DOAC-Stop or andexanet alfa, respectively, and the difference in CT was calculated (CTdiff). Results Using FXa as trigger, we detected apixaban concentrations at 20 ng/mL and above with 100% sensitivity and 100% specificity in patient samples and in vitro. Corresponding data for Ex-tem were 92% sensitivity and 100% specificity in patients, and 94% sensitivity and 100% specificity in vitro, and for RVV 97% sensitivity and 94% specificity in patients, and 97% sensitivity and 100% specificity in vitro, respectively. CTdiff data were similar. Patient sample data were obtained within 20 minutes from sampling. Conclusion Apixaban at low therapeutic concentrations was detected within 20 minutes, and with high sensitivity and specificity. A trigger based on FXa outperformed the commercial trigger Ex-tem and a trigger based on RVV. ROTEM with a FXa-based trigger is a promising method to detect apixaban bedside in acute settings.

Publisher

Georg Thieme Verlag KG

Subject

General Medicine

Reference47 articles.

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3