Diagnostic Performance of Acoustic Radiation Force Impulse Imaging in Evaluating Liver Fibrosis in Patients with Chronic Hepatitis B Infection: A Cross-Sectional Study

Author:

Bui Hoang Huu12ORCID,Vo Van Huy1ORCID,Nguyen Chuong Dinh1ORCID,Phan Sang The1,Quach Phong Tien1,Nguyen Dung Bich1

Affiliation:

1. Department of Gastroenterology, University Medical Center, Ho Chi Minh City, Vietnam

2. Department of Internal Medicine, University of Medicine and Pharmacy, Ho Chi Minh City, Vietnam

Abstract

Abstract Background Acoustic radiation force impulse point shear wave elastography (ARFI-pSWE), measuring shear-wave velocity (SWV), has been utilized to examine the liver stiffness caused by different etiologies. However, information on its reliability in staging liver fibrosis in chronic hepatitis B (CHB) patients is scarce. Purpose The aim of the study is to examine the diagnostic performance of ARFI-pSWE and determine the optimal SWV cut-off values to predict significant fibrosis (F ≥2) and cirrhosis (F4) in CHB patients. Material and Methods All 114 adult CHB patients visiting the University Medical Center, Ho Chi Minh City, Vietnam between February 2019 and March 2021 underwent liver stiffness measurement using ARFI-pSWE and FibroScan. SWV results were tested against FibroScan for sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV). The area under the receiver operating characteristic (AUROC) curve was used to identify the optimal SWV cut-off values. Results There was a strong agreement between ARFI-pSWE and FibroScan (r = 0.92, p <0.001). The optimal SWV cut-off value for detecting significant fibrosis was 1.37 m/s with an AUROC of 0.975, sensitivity of 83.3%, specificity of 100%, PPV of 100%, and NPV of 81%. The optimal cut-off value for predicting cirrhosis was 1.70 m/s with an AUROC of 0.986, sensitivity of 97%, specificity of 93%, PPV of 95%, and NPV of 96%. Conclusion ARFI-pSWE could be an effective technique for evaluating liver fibrosis in CHB patients. SWV cut-off values of 1.37 and 1.70 m/s could be used to diagnose significant fibrosis and cirrhosis, respectively.

Publisher

Georg Thieme Verlag KG

Subject

Radiology, Nuclear Medicine and imaging

Cited by 3 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3