Microtomographic Assessment of the Shaping Ability of the Hyflex CM and XP-endo Shaper Systems in Curved Root Canals

Author:

Dantas Wania Christina Figueiredo1,Marceliano-Alves Marilia Fagury Videira2,Marceliano Eduardo Fagury Videira3,Marques Eduardo Fernandes4,de Carvalho Coutinho Thais Machado2,Alves Flavio R.F.2,Martin Alexandre Sigrist De1ORCID,Pelegrine Rina Andrea1ORCID,Lopes Ricardo Tadeu5,Bueno Carlos Eduardo da Silveira1

Affiliation:

1. Department of Endodontics, São Leopoldo Mandic College, São Leopoldo Mandic Research Institute, Campinas, São Paulo, Brazil

2. Department of Endodontics and Dental Research, Iguaçu University, Nova Iguaçu, Brazil

3. Department of Dental Prosthesis, Belem General Hospital, Belém, Pará, Brazil

4. President Antonio Carlos University, Porto Nacional, ITPAC, Porto/ FAPAC, Palmas, Brazil

5. Departament of Nuclear Energy, Rio de Janeiro Federal University, Rio de Janeiro, Brazil

Abstract

Abstract Objective This study compared the shaping ability of the Hyflex CM and XP-endo Shaper rotary file systems in curved mesial canals of mandibular molars using micro-computed tomography. Material and Methods Seventeen mesial roots of extracted first mandibular molars with two independent mesial canals were scanned before and after root canal preparation with the tested rotatory file systems. Each mesial canal from the same specimen was prepared with one of the two systems. The parameters analyzed were canal centering (transportation) for the cervical, middle, and apical segments, as well as for the entire canal (0–10 mm from the apex); and canal volume increase, canal surface area increase, and unprepared canal walls for two segments, 0 to 4 mm and 0 to 10 mm from the apex. Results There was no significant difference between both systems regarding canal centering (transportation), volume increase, and unprepared canal walls for the 0 to 10 mm segment (p> 0.05); however, a significant difference was observed for the 0 to 4 mm segment (p <0.01), where the Hyflex CM left 28.46% of unprepared walls and XP-endo Shaper left 13.26%. Conclusions The shaping ability of the two tested rotatory file systems in mesial roots of first mandibular molars was similar for all parameters in all the segments evaluated, except for the 0 to 4 mm segment, where XP-endo Shaper left a smaller area of unprepared canal walls than Hyflex CM.

Funder

Fundação Carlos Chagas Filho de Amparo à Pesquisa do Estado do Rio de Janeiro (FAPERJ) and Conselho Nacional de Desenvolvimento Científico e Tecnológico

Publisher

Georg Thieme Verlag KG

Subject

General Dentistry