Metacarpal Shortening with Intramedullary Screw Fixation: A Cadaveric Study

Author:

Kwan Stephanie A.1ORCID,Wang William L.2,Tulipan Jacob E.3,Kachooei Amir3,Beredjiklian Pedro K.3,Rivlin Michael3

Affiliation:

1. Department of Orthopaedic Surgery, Rowan University SOM, Stratford, New Jersey

2. Department of Orthopaedic Surgery, Thomas Jefferson University, Philadelphia, Pennsylvania

3. Division of Hand Surgery, Rothman Orthopaedic Institute, Philadelphia, Pennsylvania

Abstract

Abstract Background Intramedullary screw fixation is a commonly used technique for the management of metacarpal fractures. However, compression across the fracture site can lead to unintentional shortening of the metacarpal. Questions/Purposes Our aim was to evaluate the risk of overshortening with differing intramedullary device designs for fixation of metacarpals. Methods The small finger metacarpal of nine fresh-frozen cadavers were included. A metacarpal neck fracture was simulated with a 5-mm osteotomy. Three different intramedullary screw designs were compared. Each screw was placed in a retrograde fashion into the intramedullary canal and the amount of shortening measured. Screws were reversed and the number of reverse turns with the screwdriver needed to release overshortening were measured. Results The average shortening at the osteotomy site was 2.5 mm. The mean shortening was 80%, 58%, and 12% for the partially threaded screw, fully threaded screw, and threaded nail, respectively. The mean differences of the distance shortened were statistically significant for the threaded nail compared with the partially and fully threaded screws. The partially threaded screw had the most shortening, while the threaded nail provided the least amount of shortening. When the screws were reversed, the screws did not disengage until the screw was fully removed from the osteotomy site. Conclusion The fully threaded nail demonstrates less shortening and possibly minimizes overshortening of fractures compared with partially threaded and fully threaded screw designs. Overshortening cannot be corrected by unscrewing the screw unless completely removed from the distal fragment. Clinical Relevance Orthopaedic surgeons may select intermedullary screws based on the design that is suited for the particular metacarpal fracture pattern.

Publisher

Georg Thieme Verlag KG

Subject

Orthopedics and Sports Medicine,Surgery

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3