Uncovering Discrepancies in IV Vancomycin Infusion Records between Pump Logs and EHR Documentation

Author:

Tung Tsan-Hua1,DeLaurentis Poching2,Yih Yuehwern1

Affiliation:

1. School of Industrial Engineering, College of Engineering, Purdue University, West Lafayette, Indiana, United States

2. Regenstrief Center for Healthcare Engineering, Purdue University, West Lafayette, Indiana, United States

Abstract

Abstract Background Infusion start time, completion time, and interruptions are the key data points needed in both area under the concentration–time curve (AUC)- and trough-based vancomycin therapeutic drug monitoring (TDM). However, little is known about the accuracy of documented times of drug infusions compared with automated recorded events in the infusion pump system. A traditional approach of direct observations of infusion practice is resource intensive and impractical to scale. We need a new methodology to leverage the infusion pump event logs to understand the prevalence of timestamp discrepancies as documented in the electronic health records (EHRs). Objectives We aimed to analyze timestamp discrepancies between EHR documentation (the information used for clinical decision making) and pump event logs (actual administration process) for vancomycin treatment as it may lead to suboptimal data used for therapeutic decisions. Methods We used process mining to study the conformance between pump event logs and EHR data for a single hospital in the United States from July to December 2016. An algorithm was developed to link records belonging to the same infusions. We analyzed discrepancies in infusion start time, completion time, and interruptions. Results Of the 1,858 infusions, 19.1% had infusion start time discrepancy more than ± 10 minutes. Of the 487 infusion interruptions, 2.5% lasted for more than 20 minutes before the infusion resumed. 24.2% (312 of 1,287) of 1-hour infusions and 32% (114 of 359) of 2-hour infusions had over 10-minute completion time discrepancy. We believe those discrepancies are inherent part of the current EHR documentation process commonly found in hospitals, not unique to the care facility under study. Conclusion We demonstrated pump event logs and EHR data can be utilized to study time discrepancies in infusion administration at scale. Such discrepancy should be further investigated at different hospitals to address the prevalence of the problem and improvement effort.

Publisher

Georg Thieme Verlag KG

Subject

Health Information Management,Computer Science Applications,Health Informatics

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3