A Biomechanical Comparison of Fixation Techniques in Metacarpal Shaft Fractures

Author:

Albanese Kevin M.1ORCID,Schreck Michael J.1,Werner Frederick W.1ORCID,Esper Garrett W.1,Ordway Nathaniel R.1ORCID

Affiliation:

1. Department of Orthopedic Surgery, SUNY Upstate Medical University, Syracuse, New York

Abstract

Abstract Background Typically, metacarpal shaft fractures are treated with closed reduction percutaneous pinning, intramedullary nails, or plate fixation. Recently some surgeons have begun using intramedullary headless compression screws. Questions/Purposes The purpose of this study was to compare intramedullary screw fixation to K-wire fixation, which is the standard of care in a transverse metacarpal midshaft fracture, using a cadaveric model. Our hypothesis was that intramedullary screw fixation would have a biomechanical advantage (higher stiffness and peak load to failure) when compared with dual Kirschner wire fixation of transverse metacarpal shaft fractures. Methods Four-point bend testing was performed to compare stiffness and failure load values of seven paired 2nd and 3rd metacarpals instrumented with headless intramedullary compression screw fixation or Kirschner wire fixation. Similar testing was performed on 14 unpaired 4th metacarpals. Results There was no significant difference in peak load (p = 0.60) or stiffness (p = 0.85) between fixation groups for the 2nd and 3rd instrumented metacarpals. For the instrumented 4th metacarpals, there was no significant difference in peak load (p = 0.14), but the stiffness was significantly greater (p = 0.01) for the compression screw group compared with the Kirschner wire fixation. Conclusions/Clinical Relevance In this study, the load to failure was not different between the two fixation methods and likely both techniques can sustain physiologic loads needed for rehabilitation. The greater stiffness in the 4th metacarpal compression screw group may be related to the smaller canal morphology than in the 2nd and 3rd metacarpals. Larger diameter screws may be needed to obtain a better fit particularly in the 2nd and 3rd metacarpals.

Funder

DePuy Synthes as a part of a Resident Initiated Research Grant

Publisher

Georg Thieme Verlag KG

Subject

Orthopedics and Sports Medicine,Surgery

Reference17 articles.

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3