Effect of Different Root Canal Drying Protocols on the Bond Strength of Two Bioceramic Sealers

Author:

Frasquetti Karine Santos1,Piasecki Lucila2,Kowalczuck Alexandre1ORCID,Carneiro Everdan1,Westphalen Vânia Portela Ditzel1,Neto Ulisses Xavier da Silva1

Affiliation:

1. Postgraduate Program in Endodontics, School of Health and Biosciences of PUCPR, Curitiba, Paraná, Brazil

2. Department of Periodontics and Endodontics, School of Dental Medicine, University at Buffalo, Buffalo, New York, United States

Abstract

Summary Objectives This study evaluated in vitro the effect of two different drying protocols on the dentin bond strength of two different bioceramic sealers (Sealer Plus BC [SP] and Bio C Sealer [BCS]). Bond strength and failure mode were evaluated according to the sealer, drying protocol, and root canal third. Materials and Methods Sixty extracted human mandibular single-rooted premolars were selected after anatomical standardization. The crowns were sectioned and root canals were prepared. Roots were randomly divided into four groups (n = 15 each). Each group was assigned a combination of one of the evaluated sealers (SP or BCS) and one of the drying protocols: canals dried with paper points (PP) or irrigation with saline followed by aspiration with silicon cannulas (IA). Obturations were performed using a single-cone technique. The teeth were temporized and stored for 7 days (100% humidity, 37°C). Roots were cut to obtain 2 mm thick discs for each third (coronal, middle, and apical). Push-out tests were performed on a universal testing machine, and the bond strength (MPa) of each specimen was calculated by dividing the load (N) by the interface area. Failure type was assessed under ×4 magnification. Statistical Analysis Data were statistically analyzed with a significance set at 5%. An analysis of variance test followed by the Games-Howell post-hoc test was used to compare the mean values between the groups and the interaction of the variables. Results The predominant failure type was cohesive, followed by mixed failure and adhesive in all groups. The apical third presented the highest bond strength (p < 0.05) regardless of the group, followed by the middle and coronal thirds. Overall, the SP PP group had the highest mean bond strength (p < 0.01), but the SP sealer was negatively affected by the IA drying protocol in the coronal and middle thirds. The BCS presented similar results within the third stage, regardless of the drying protocol. Conclusions Sealer Plus BC had a higher bond strength than Bio C Sealer, but it was negatively affected by the irrigation-aspiration protocol in the coronal and middle thirds. For the apical third, there was no difference between the groups; thus, a similar bond strength was observed regardless of the drying protocol or sealer.

Publisher

Georg Thieme Verlag KG

Subject

General Dentistry

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3