Influence of Kirschner-Wire Insertion Angle on Construct Biomechanics following Tibial Tuberosity Osteotomy Fixation in Dogs

Author:

Hawbecker Tyler J.1,Duffy Daniel J.1ORCID,Chang Yi-Jen1,Moore George E.2

Affiliation:

1. Department of Clinical Sciences, College of Veterinary Medicine, North Carolina State University, Raleigh, North Carolina, United States

2. Department of Veterinary Administration, Veterinary Administration, College of Veterinary Medicine, Purdue University, West Lafayette, Indiana, United States

Abstract

Abstract Objectives The aim of this study was to evaluate the effect of Kirschner wire insertion angle on the biomechanical characteristics following tibial tuberosity osteotomy fixation in dogs. Study Design Twelve pairs of cadaveric tibia were harvested and randomly assigned to two treatment groups. Kirschner wires were placed either transversely (0 degrees) or placed caudodistally (30 degrees) with respect to the tibial tuberosity osteotomy. Each limb acted as its own respective control. Radiographic analysis allowed for the calculation of Kirschner wire insertion angle variance. Constructs were tested to monotonic failure while evaluating yield, peak, and failure forces, construct stiffness, and failure mode. Results Kirschner wire insertion angles were 1.1 ± 2.2 degrees and 30.5 ± 2.3 degrees, respectively, for 0-degree and 30-degree groups (p <0.0001). Yield (p = 0.0095), peak (p <0.024) and failure loads (p <0.030) were all significantly greater for Kirschner wires inserted at an angle of 0 degrees compared with 30 degrees. Construct stiffness did not differ regardless of insertion angle (p = 0.068). Failure mode did not differ (p = 0.87) with tibial tuberosity avulsion and Kirschner wire pull-out seen in the majority of constructs (67%). Conclusion Kirschner wires placed transversely (0 degrees) for tibial tuberosity osteotomy fixation were biomechanically superior, increasing yield, peak, and failure forces by 1.6 times, 1.3 times, and 1.4 times, respectively, to those placed in a caudodistal (30 degrees) orientation. Kirschner wire insertion angle is an important consideration following tibial tuberosity osteotomy in dogs, with Kirschner wires placed at 0 degrees conferring increased resistance of the repair to construct deformation.

Publisher

Georg Thieme Verlag KG

Subject

General Veterinary,Animal Science and Zoology

Reference19 articles.

1. Canine patellar luxation;J K Roush;Vet Clin North Am Small Anim Pract,1993

2. Canine medial patellar luxation;K L Perry;J Small Anim Pract,2021

3. Patellar luxation: pathogenesis and surgical correction;G Harasen;Can Vet J,2006

4. Retrospective risk factor assessment for complication following tibial tuberosity transposition in 137 canine stifles with medial patellar luxation;N J Stanke;Can Vet J,2014

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3