Sutureless Valve in Bicuspid Aortic Stenosis: Modified Technique and Midterm Outcome

Author:

Li Han-Yan1,Tsai Feng-Chun1,Lu Cheng-Hui2,Chou An-Hsun3,Huang Huei-Chiun4,Gersak Borut5

Affiliation:

1. Division of Thoracic and Cardiovascular Surgery, Chang Gung Memorial Hospital, Linkou Medical Center, Taoyuan, Taiwan

2. Division of Cardiology, Chang Gung Memorial Hospital, Linkou Medical Center, Taoyuan, Taiwan

3. Department of Anesthesiology, Chang Gung Memorial Hospital, Linkou Medical Center, Taoyuan, Taiwan

4. Department of Nursing, Chang Gung Memorial Hospital, Linkou Medical Center, Taoyuan, Taiwan

5. University of Ljubljana School of Medicine, Chair of Surgery, Ljubljana, Slovenia Nisteri, Medicine and Research, Ljubljana, Slovenia

Abstract

Abstract Background The sutureless valve has gained popularity for degenerative aortic valve stenosis but not congenital bicuspid aortic valve (BAV) due to anatomical challenges. We reviewed our modified implant techniques for patients with BAV. Methods From June 2015 to June 2019, 66 patients with aortic valve stenosis were treated with the Perceval sutureless valve, 20 of whom had BAV. The demographics, type of BAV (the Sievers classification), and associated pathologies, surgical outcomes, and midterm hemodynamics were recorded. Results The median age was 64 (range: 49–81) years and the Society of Thoracic Surgeons score was 2.186 (range: 0.407–6.384). Annular plication was performed in 9 (75%) of 12 type 0 and 3 (37.5%) of 8 type I, with implanted valve sizes of M, L, and XL in 6, 10, 4 cases, respectively. Three patients, all type 0 in the initial learning periods, required intraoperative redeployment due to malposition of the valve. The final implant was successful in all without conversion to traditional prosthesis. The median extubation time was 4 hours and the durations of intensive care unit and hospital stay were 1 and 6 days. At a median follow-up of 46 (23–72) months, there was one late mortality due to hemorrhagic stroke sequel. The last echo revealed none had more than mild paravalvular leakage and the mean transvalvular pressure gradient remained stable at 9.70 (range: 6.94–15.0) mm Hg. Conclusions The sutureless valve can achieve satisfactory outcomes in BAV without paravalvular leakage and excellent hemodynamics. It may serve as the benchmark for transcatheter aortic valve implantation in this unique population.

Publisher

Georg Thieme Verlag KG

Subject

Cardiology and Cardiovascular Medicine,Pulmonary and Respiratory Medicine,Surgery

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3