The Effect of Salivary pH on the Flexural Strength and Surface Properties of CAD/CAM Denture Base Materials

Author:

Alzaid Maryam1,AlToraibily Fatemah1ORCID,Al-Qarni Faisal D.2ORCID,Al-Thobity Ahmad M.2ORCID,Akhtar Sultan3,Ali Saqib4ORCID,Al-Harbi Fahad A.2,Gad Mohammed M.2

Affiliation:

1. College of Dentistry, Imam Abdulrahman Bin Faisal University, Dammam, Saudi Arabia

2. Department of Substitutive Dental Sciences, College of Dentistry, Imam Abdulrahman Bin Faisal University, Dammam, Saudi Arabia

3. Department of Biophysics, Institute for Research and Medical Consultations (IRMC), Imam Abdulrahman Bin Faisal University, Dammam, Saudi Arabia

4. Department of Biomedical Dental Sciences, College of Dentistry, Imam Abdulrahman Bin Faisal University, Dammam, Saudi Arabia

Abstract

Abstract Objectives This study aimed to evaluate the influence of different salivary pH on flexural strength, hardness, and surface roughness of computer-aided design and computer-aided manufacturing (CAD/CAM) milled and three-dimensional (3D)-printed denture base resins. Methods One heat-polymerized, two CAD/CAM milled (IvoCad, AvaDent), and two 3D-printed (FormLabs, NextDent) denture base resins were fabricated and divided into five groups (n = 10) according to the solutions: three groups were immersed in different salivary pH (5.7, 7.0, or 8.3), one group was immersed in distilled water (DW) as a positive control, and one group had no immersion (negative control). All immersions were performed at 37°C for 90 days. Flexural strength, hardness, and surface roughness were measured before and after immersion. Data was analyzed with analysis of variance and post hoc Tukey's test (α = 0.05). Results After immersion, all specimens had lower flexural strength values when compared with those with no immersion. Comparing the immersion groups, the highest flexural strength value (93.96 ± 3.18 MPa) was recorded with IvoCad after immersion in DW while the lowest value (60.43 ± 2.66 MPa) was recorded with NextDent after being immersed in 7.0 pH saliva. All specimens had significant decrease in hardness except IvoCad and AvaDent specimens where both presented the highest surface hardness (53.76 ± 1.60 Vickers hardness number [VHN]) after immersion in DW while NextDent showed the lowest hardness value (24.91 ± 2.13 VHN) after being immersed in 8.3 pH saliva. There was statistically significant difference between the baseline and different artificial salivary pH solutions in terms of surfaces roughness, with the highest surface roughness were found in 3D-printed resin materials. Conclusion After exposure to artificial saliva with different salivary pH, the milled CAD/CAM denture base resins showed higher flexural strength, hardness, and lesser surface roughness than conventional and 3D-printed denture base resins.

Publisher

Georg Thieme Verlag KG

Subject

General Dentistry

Reference42 articles.

1. PMMA denture base material enhancement: a review of fiber, filler, and nanofiller addition;M M Gad;Int J Nanomed,2017

2. Effect of heat polymerization conditions and microwave on the flexural strength of polymethyl methacrylate;S E Ozkir;Eur J Dent,2018

3. Effects of SiO2 incorporation on the flexural properties of a denture base resin: an in vitro study;S T Alzayyat;Eur J Dent,2022

4. Comparative evaluation of effect of water absorption on the surface properties of heat cure acrylic: an in vitro study;G S Chandu;J Int Oral Health,2015

5. Influence of artificial accelerated aging on dimensional stability of acrylic resins submitted to different storage protocols;LdaF Garcia;J Prosthodont,2010

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3