Evaluation of Hypervascular Focal Liver Lesions Utilizing Virtual Monoenergetic Images from Third-Generation Dual-Source Dual-Energy Computed Tomography

Author:

Narappulan Niyas1,Arunachalam Venkatesh Kasi1,Alavandar Ezhilmathi1,Selvaraja Swathigha1,Renganathan Rupa1,Cherian Mathew1

Affiliation:

1. Department of Radiology, Kovai Medical Center and Hospital, Coimbatore, India

Abstract

Abstract Objectives The purpose of our study was to evaluate the virtual monochromatic imaging in detecting hypervascular focal liver lesions in the late arterial phase with third-generation dual-source dual-energy computed tomography and to assess its image quality. Materials and Methods In our study, 80 patients were included. Contrast-enhanced images in the late arterial phase (in the dual-energy mode) were acquired and were post-processed in Syngo, via workstation, using Monoenergetic + software. Five sets of images, one polychromatic energy image (corresponding to 120 kVp single-energy image) and four virtual monoenergetic image (VMI) sets at 40, 50, 60, and 70 keV levels, were generated. All these images were analyzed both objectively and subjectively. The attenuation values were measured, and the contrast-to-noise ratio (CNR) of liver and tumor were measured and compared objectively in each dataset. Image noise, image contrast, and diagnostic confidence for liver lesion detection were analyzed subjectively using a five-point scale system. Statistical analysis was performed using Kolmogorov–Smirnov, analysis of variance, and Kruskal–Wallis tests. Results Among the VMI, maximum image noise was observed in the 40 keV image, with a gradual reduction in the image noise being noted with an increase in the VMI energy. The CNR of the hepatic parenchyma and the tumor gradually increased with a reduction in VMI energy from 70 to 40 keV. On subjective analysis, image contrast and image noise were observed to be more in low VMI datasets. In lesion detection, diagnostic confidence with an excellent confidence level was observed with a decrease in VMI energy. Conclusion VMI datasets of 40 to 70 keV from third-generation dual-source DECT provide superior diagnostic accuracy for detecting hypervascular liver lesions. Considering the image noise and lesion detection rate among the VMI datasets, 60 keV VMI is the most helpful dataset for increased liver lesion detection with good image quality.

Publisher

Georg Thieme Verlag KG

Subject

General Medicine,General Chemistry

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

1. Dual-Energy Computed Tomography Applications in the Abdomen;Journal of Gastrointestinal and Abdominal Radiology;2022-07

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com