Relationship between the Prenatal Diagnosis of Placenta Acreta Spectrum and Lower Use of Blood Components

Author:

Pavón-Gomez Néstor12ORCID,López Rita12ORCID,Altamirano Luis2ORCID,Cabrera Sugey Bravo1ORCID,Rosales Gusmara Porras1ORCID,Chamorro Sergio12ORCID,González Karen1ORCID,Morales Amparo1ORCID,Maya Juliana3ORCID,Sinisterra Stiven4ORCID,Nieto-Calvache Albaro José25ORCID

Affiliation:

1. Hospital Bertha Calderón Roque, Managua, Nicaragua

2. Latin American Group for the Study of Placenta Accreta Spectrum, Cali, Colombia

3. Programa de Medicina, Facultad de Ciencias de la Salud, Universidad Icesi, Cali, Colombia

4. Centro de Investigaciones Clínicas, Fundación Valle del Lili, Cali, Colombia

5. Clínica de Espectro de Acretismo Placentario, Fundación Valle del Lili, Cali, Colombia

Abstract

Abstract Objective To describe the clinical results of patients admitted and managed as cases of placenta accreta spectrum (PAS) at a Central American public hospital and the influence of the prenatal diagnosis on the condition. Materials and Methods A retrospective analysis of PAS patients treated at Hospital Bertha Calderón Roque, in Managua, Nicaragua, between June 2017 and September 2021. The diagnostic criteria used were those of the International Federation of Gynecology and Obstetrics (Fédération Internationale de Gynécologie et d'Obstétrique, FIGO, in French). The population was divided into patients with a prenatal ultrasonographic diagnosis of PAS (group 1) and those whose the diagnosis of PAS was established at the time of the caesarean section (group 2). Results: During the search, we found 103 cases with a histological and/or clinical diagnosis of PAS; groups 1 and 2 were composed of 51 and 52 patients respectively. Regarding the clinical results of both groups, the patients in group 1 presented a lower frequency of transfusions (56.9% versus 96.1% in group 2), use of a lower number of red blood cell units (RBCUs) among those undergoing transfusions (median: 1; interquartile range: [IQR]: 0–4 versus median: 3; [IQR]: 2–4] in group 2), and lower frequency of 4 or more RBCU transfusions (29.4% versus 46.1% in group 2). Group 1 also exhibited a non-significant trend toward a lower volume of blood loss (1,000 mL [IQR]: 750–2,000 mL versus 1,500 mL [IQR]: 1,200–1,800 mL in group 2), and lower requirement of pelvic packing (1.9% versus 7.7% in group 2). Conclusion Establishing a prenatal diagnosis of PAS is related to a lower frequency of transfusions. We observed a high frequency of prenatal diagnostic failures of PAS. It is a priority to improve prenatal detection of this disease.

Publisher

Georg Thieme Verlag KG

Subject

Obstetrics and Gynecology

Cited by 3 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3