Affiliation:
1. Department of Orthopaedic Surgery, Lenox Hill Hospital, Northwell Health, New York
Abstract
AbstractTotal knee arthroplasty (TKA) in cases of complex deformity (e.g., ligamentous laxity, posttraumatic arthritis) may require prostheses with inherent varus–valgus stability greater than that of traditional posterior stabilized or cruciate-retaining implants. Here, we investigate the clinical and radiographic outcomes of TKA using a midlevel constraint (MLC) prosthesis. A retrospective review of 53 patients (62 knees) who underwent primary TKA with an MLC implant was performed. Short tibial stem extensions were utilized in 49 knees, and 13 knees received no stem extension. Mean follow-up time was 31.6 months (standard deviation [SD] = 10.0, range = 24–53). Preoperative and postoperative range of motion (ROM) were assessed. Plain radiographs were reviewed for alignment, radiolucent lines, component loosening, and osteolysis. Patients who developed postoperative arthrofibrosis underwent manipulation under anesthesia (MUA). Failure was defined as instability, component loosening, or need for revision surgery. Mean ROM significantly improved from 114.1 degrees (SD = 19.7 degrees) preoperatively to 123.5 degrees (SD = 12.2 degrees) at final follow-up (t = −3.43, p = 0.001). Thirty-seven knees initially presented with varus deformity (mean = 7.5 degrees, SD = 4.8 degrees), whereas 23 had valgus deformity (mean = 10.6 degrees, SD = 6.5 degrees), and 2 knees had neutral alignment. Following surgery, mean alignment was 4.3 degrees valgus (SD = 1.7 degrees, range = 0–8 degrees), representing a statistically significant improvement (t = 5.29, p < 0.001). Six patients (9.7%) developed arthrofibrosis requiring MUA, which was irrespective of baseline ROM (p = 0.92) and consistent with 12% incidence reported in the literature. There were no significant differences in postoperative ROM (t = 0.38, p = 0.71), alignment (t = −0.22, p = 0.83), or incidence of arthrofibrosis (χ2 = 0.07, p = 0.79) between short-stemmed and nonstemmed implants. There was no radiographic evidence of radiolucent lines, component loosening, or osteolysis in any patients. No patients required revision surgery. Use of an MLC prosthesis with primary femoral component in TKA resulted in satisfactory clinical and radiographic results with no evidence of component loosening, osteolysis, instability, or need for revision at minimum 2-year follow-up.
Subject
Orthopedics and Sports Medicine,Surgery
Reference30 articles.
1. Total knee arthroplasty volume, utilization, and outcomes among Medicare beneficiaries, 1991-2010;P Cram;JAMA,2012
2. Projections of primary and revision hip and knee arthroplasty in the United States from 2005 to 2030;S Kurtz;J Bone Joint Surg Am,2007
3. Varus-valgus constrained implants in total knee arthroplasty: indications and technique;P Adravanti;Acta Biomed,2017
4. Why are total knee arthroplasties failing today—has anything changed after 10 years?;P F Sharkey;J Arthroplasty,2014
5. Failure in total knee arthroplasty: mechanisms, revisions, and results;H U Cameron;Clin Orthop Relat Res,1982
Cited by
3 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献