Stability with a Constrained Posterior Stabilized Primary Total Knee Arthroplasty Does Not Compromise Durability

Author:

Yohe Nicholas1,Vanderbrook Douglas J.1,Sherman Alain E.1ORCID,Papas Paraskevi Vivian1,Scuderi Giles R.1

Affiliation:

1. Department of Orthopaedic Surgery, Lenox Hill Hospital, Northwell Health, New York

Abstract

AbstractTotal knee arthroplasty (TKA) in cases of complex deformity (e.g., ligamentous laxity, posttraumatic arthritis) may require prostheses with inherent varus–valgus stability greater than that of traditional posterior stabilized or cruciate-retaining implants. Here, we investigate the clinical and radiographic outcomes of TKA using a midlevel constraint (MLC) prosthesis. A retrospective review of 53 patients (62 knees) who underwent primary TKA with an MLC implant was performed. Short tibial stem extensions were utilized in 49 knees, and 13 knees received no stem extension. Mean follow-up time was 31.6 months (standard deviation [SD] = 10.0, range = 24–53). Preoperative and postoperative range of motion (ROM) were assessed. Plain radiographs were reviewed for alignment, radiolucent lines, component loosening, and osteolysis. Patients who developed postoperative arthrofibrosis underwent manipulation under anesthesia (MUA). Failure was defined as instability, component loosening, or need for revision surgery. Mean ROM significantly improved from 114.1 degrees (SD = 19.7 degrees) preoperatively to 123.5 degrees (SD = 12.2 degrees) at final follow-up (t = −3.43, p = 0.001). Thirty-seven knees initially presented with varus deformity (mean = 7.5 degrees, SD = 4.8 degrees), whereas 23 had valgus deformity (mean = 10.6 degrees, SD = 6.5 degrees), and 2 knees had neutral alignment. Following surgery, mean alignment was 4.3 degrees valgus (SD = 1.7 degrees, range = 0–8 degrees), representing a statistically significant improvement (t = 5.29, p < 0.001). Six patients (9.7%) developed arthrofibrosis requiring MUA, which was irrespective of baseline ROM (p = 0.92) and consistent with 12% incidence reported in the literature. There were no significant differences in postoperative ROM (t = 0.38, p = 0.71), alignment (t = −0.22, p = 0.83), or incidence of arthrofibrosis (χ2 = 0.07, p = 0.79) between short-stemmed and nonstemmed implants. There was no radiographic evidence of radiolucent lines, component loosening, or osteolysis in any patients. No patients required revision surgery. Use of an MLC prosthesis with primary femoral component in TKA resulted in satisfactory clinical and radiographic results with no evidence of component loosening, osteolysis, instability, or need for revision at minimum 2-year follow-up.

Publisher

Georg Thieme Verlag KG

Subject

Orthopedics and Sports Medicine,Surgery

Reference30 articles.

1. Total knee arthroplasty volume, utilization, and outcomes among Medicare beneficiaries, 1991-2010;P Cram;JAMA,2012

2. Projections of primary and revision hip and knee arthroplasty in the United States from 2005 to 2030;S Kurtz;J Bone Joint Surg Am,2007

3. Varus-valgus constrained implants in total knee arthroplasty: indications and technique;P Adravanti;Acta Biomed,2017

4. Why are total knee arthroplasties failing today—has anything changed after 10 years?;P F Sharkey;J Arthroplasty,2014

5. Failure in total knee arthroplasty: mechanisms, revisions, and results;H U Cameron;Clin Orthop Relat Res,1982

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

1. Intraoperative Medial Instability During Total Knee Arthroplasty;Orthopedic Clinics of North America;2024-01

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3