Resonant Acoustic Rheometry to Measure Coagulation Kinetics in Hemophilia A and Healthy Plasma: A Novel Viscoelastic Method

Author:

Li Weiping1,Hobson Eric C.1,Bunch Connor M.2,Miller Joseph B.2,Nehme Jimmy2,Kwaan Hau C.3,Walsh Mark M.4,McCurdy Michael T.5,Aversa John G.6,Thomas Anthony V.7,Zackariya Nuha7,Thomas Samuel J.4,Smith Stephanie A.8,Cook Bernard C.9,Boyd Bryan9,Stegemann Jan P.1,Deng Cheri X.1

Affiliation:

1. Department of Biomedical Engineering, University of Michigan, Ann Arbor, Michigan

2. Department of Emergency Medicine and Internal Medicine, Henry Ford Hospital, Detroit, Michigan

3. Division of Hematology and Oncology, Department of Medicine, Northwestern University Feinberg School of Medicine, Chicago, Illinois

4. Department of Emergency Medicine, St. Joseph Regional Medical Center, Mishawaka, Indiana

5. Division of Pulmonary and Critical Care Medicine, Department of Medicine, University of Maryland School of Medicine, Baltimore, Maryland

6. Department of Surgery, Indiana University School of Medicine, Indianapolis, Indiana

7. Indiana University School of Medicine South Bend Campus, Notre Dame, Indiana

8. Department of Biological Chemistry, Michigan Medicine, Ann Arbor, Michigan

9. Department of Pathology, Henry Ford Hospital, Detroit, Michigan

Abstract

AbstractCompared with conventional coagulation tests and factor-specific assays, viscoelastic hemostatic assays (VHAs) can provide a more thorough evaluation of clot formation and lysis but have several limitations including clot deformation. In this proof-of-concept study, we test a noncontact technique, termed resonant acoustic rheometry (RAR), for measuring the kinetics of human plasma coagulation. Specifically, RAR utilizes a dual-mode ultrasound technique to induce and detect surface oscillation of blood samples without direct physical contact and measures the resonant frequency of the surface oscillation over time, which is reflective of the viscoelasticity of the sample. Analysis of RAR results of normal plasma allowed defining a set of parameters for quantifying coagulation. RAR detected a flat-line tracing of resonant frequency in hemophilia A plasma that was corrected with the addition of tissue factor. Our RAR results captured the kinetics of plasma coagulation and the newly defined RAR parameters correlated with increasing tissue factor concentration in both healthy and hemophilia A plasma. These findings demonstrate the feasibility of RAR as a novel approach for VHA, providing the foundation for future studies to compare RAR parameters to conventional coagulation tests, factor-specific assays, and VHA parameters.

Publisher

Georg Thieme Verlag KG

Subject

Cardiology and Cardiovascular Medicine,Hematology

Reference35 articles.

1. Clinical utility of viscoelastic testing (TEG and ROTEM analyzers) in the management of old and new therapies for hemophilia;S Ramiz;Am J Hematol,2019

2. Whole blood clot formation phenotypes in hemophilia A and rare coagulation disorders. Patterns of response to recombinant factor VIIa;B Sørensen;J Thromb Haemost,2004

3. The rare inherited coagulation disorders;P H Bolton-Maggs;Pediatr Blood Cancer,2013

4. Global coagulation assays in hemophilia A: a comparison to conventional assays;S Aghighi;Res Pract Thromb Haemost,2019

5. The utility of thromboelastography in inherited and acquired bleeding disorders;K Nogami;Br J Haematol,2016

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3