The Optimal Choice of Technique for Stereotactic Radiosurgery—A LINAC-Based Dosimetric Study between DCA, DCA-SSO, DCA-SSO-VDR, and VMAT

Author:

Venugopal Ramya1,S. Sowmya Narayanan1,Tiwari Richa2,Narayanan Geeta S.2,Vishwanathan Bhaskar2

Affiliation:

1. Department of Radiation Physics, Vydehi Institute of Medical Sciences and Research Centre, Bangalore, Karnataka, India

2. Department of Radiation Oncology, Vydehi Institute of Medical Sciences and Research Centre, Bangalore, Karnataka, India

Abstract

Abstract Introduction Advanced radiation therapy delivery techniques require greater understanding of various planning sequences and methods. The aim of this study is to determine a class solution that finds the best possible technique to deliver for stereotactic radiosurgery between dynamic conformal arc (DCA) techniques using various options such as DCA, DCA + SSO (segment shape optimization), and DCA + SSO + VDR (variable dose rate) using noncoplanar beam arrangement and volumetric modulated arc therapy (VMAT) using coplanar beams. Materials and Methods In this dosimetric study, 11 brain cases were retrospectively planned for various techniques and analyzed for the Paddick conformity index (CI), Radiation Therapy Oncology Group homogeneity index (HI), Paddick gradient index (GI), treatment time in terms of monitor units (MU) and normal brain dose (V12Gy). The paired t-test was performed to know the statistical significance between the techniques. Results In terms of CI, GI, and control of the normal brain dose, the VMAT plan was superior to other techniques. But, HI was found to be better with DCA. Above all, VMAT delivered higher MU than any other technique. The p-values between DCA + SSO and DCA, DCA + SSO + VDR and DCA + SSO, and VMAT and DCA + SSO + VDR are as follows: CI: 0.0004, 0.015, and 0.03; GI: 0.03, 0.33, and 0.29; HI: 0.008, 0.04, and 0.06; V12 Gy of normal brain: 0.1, 0.01, 0.38. VMAT requires approximately 41 ± 17% more MU than DCA + SSO + VDR. Conclusion VMAT using coplanar beams is preferable among all the techniques, considering the dosimetric parameters studied. If VMAT is not available in the facility, DCA + SSO + VDR technique using non coplanar beams can be used to deliver SRS treatment.

Publisher

Georg Thieme Verlag KG

Subject

Critical Care Nursing,Pediatrics

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3