DeGIR Quality Report 2019: Report on the treatment quality of minimally invasive methods – Interventional therapy (EVAR) of abdominal aortic aneurysms

Author:

Frenzel Felix1ORCID,Bücker Arno1,Paprottka Philipp2,Nadjiri Jonathan2,Mahnken Andreas H.3,Massmann Alexander1,Minko Peter1,Heuser Lothar J.4

Affiliation:

1. Clinic of Diagnostic and Interventional Radiology, Saarland University Hospital and Saarland University Faculty of Medicine, Homburg, Germany

2. Department of Interventional Radiology, Technical University of Munich, München, Germany

3. Diagnostic and Interventional Radiology, University Hospital of Gießen and Marburg Campus Marburg, Germany

4. Dept. of Diagnostic und Interventional Radiology, Im Pastoratsbusch 49, Bochum, Germany

Abstract

Purpose To analyze the quality of endovascular aortic aneurysm repair using the data of the DeGIR quality management system. Comparison of data between 2011 and 2019. Materials and Methods A retrospective analysis of all data registered in the DeGIR quality management system of the year 2019 was performed regarding the treatment quality for endovascular aortic aneurysm repair. Registration of data was voluntary. As quality parameters indication, treatment process data and quality of results were examined. The latter was judged by treatment success, complication rates and radiation exposure. Results Out of 189 590 data sets overall 1639 cases of EVAR were registered; compared to 2011 this was an increase of 472 cases. 5.9 % of these cases encompassed emergency treatments. The most frequent indication was an abdominal aneurysm with 72 % of cases. In 54 % of cases, the aortic diameter ranged 50–70 mm. The rates for technical success, over all complications and major complications were 92.8 %, 6.7 % and 6.0 % respectively for all EVAR including emergency indications. In general, EVAR yielded a mortality rate of 1.2 % while emergency procedures had a mortality rate of 7.3 %. Median dose area product and fluoroscopy time were 10 503 cGy × cm2 and 20 minutes respectively at a mean procedure time of 114 minutes. Conclusion Data analysis of the DeGIR quality management system persistently showed a very high technical success rate for endovascular aortic aneurysm repair performed by interventional radiologists accompanied by a low complication rate. Key Points  Citation Format

Publisher

Georg Thieme Verlag KG

Subject

Radiology, Nuclear Medicine and imaging

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3