Ultrasound-detected venous changes associated with peripheral intravenous placement in children

Author:

Goel Dewansh1,Smitthimedhin Anilawan1,Yadav Bhupender1,Vellody Ranjith1,Lele Meenal1,Meagher Elisabeth1,Yarmolenko Pavel1,Sharma Karun V.1

Affiliation:

1. Children's National Medical Center, Washington, DC

Abstract

HIGHLIGHTS Ultrasound shows several venous changes in pediatric PIV-containing veins. Changes were visualized by ultrasound in the absence of physical exam findings. Venous luminal narrowing, wall thickening, and thrombosis may explain PIV failure. Background: Peripheral intravenous catheters (PIVs) are routinely used for venous access in hospitalized pediatric patients to administer fluids and medications and to aspirate blood. Unfortunately, PIVs do not remain functional for the entire duration of intravascular need. We hypothesized that PIV malfunction may be related to venous changes that can be visualized with ultrasound (US) imaging. The purpose of this study was to describe and document such changes in pediatric patients. Methods: This Institutional Review Board-approved study was performed at a tertiary pediatric medical center. Patients underwent US scans of their PIV-containing veins, documenting venous characteristics such as depth, diameter, wall thickness, blood flow, valves, branch points, and presence of thrombus. Patient demographics and PIV characteristics were also recorded. Results: Data from 30 patients including 12 males and 18 females with a mean age of 11 years were analyzed. Mean venous depth and diameter were 2.07 ± 0.13 and 2.02 ± 0.18 mm, respectively. Mean PIV dwell time at time of evaluation was 3.3 days. PIV-associated venous changes were seen in 73% of accessed veins and included lumen narrowing (47%), wall thickening (33%), presence of thrombus (20%), and absence of blood flow around the PIV tip (40%). Conclusion: PIV-associated venous changes are seen with US in the majority of pediatric patients with indwelling PIVs but are not necessarily appreciated on physical exam. These changes may help explain the high rate of pediatric PIV device failure. Given the small sample size, further investigation is needed to better characterize PIV-associated venous changes in children.

Publisher

Mark Allen Group

Subject

General Nursing

Cited by 7 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3