The potential role of through the needle PIVC insertion in reducing early catheter contamination

Author:

Anstett Michael1,Brainard Robert E.2

Affiliation:

1. Chief Clinical Officer, SkyDance Vascular, Inc, Louisville, KY

2. Department of Physiology and Biophysics, University of Louisville, KY

Abstract

HIGHLIGHTS Over-the-needle (OTN) PIVC devices are at inherent risk of insertion related skin contamination. Through-the-needle (TTN) catheter deployment resulted in no measurable contamination in this study. OTN catheters were 1.67 times more likely to be contaminated than TTN in this study. Aim: To compare a traditional over-the-needle peripheral intravenous catheter device to a through-the-needle (TTN) peripheral intravenous catheter device for early bacterial contamination during insertion. Methods: Five TTN test devices (OspreyIV 20 g SkyDance Vascular, Inc) and 5 OTN comparative devices (Insyte Autoguard 20 g Becton Dickinson) were aseptically inserted through targeted zones inoculated with 1 mL aliquot suspension of approximately 1 × 10 CFU of Staphylococcus aureus among 3 healthy sheep. Immediately after insertion, each study catheter was surgically removed from the surrounding tissue and cultured for the presence of Staphylococcus aureus inoculum that may have been transferred to the catheter during insertion. Results: Final culture results of the 5 test articles found no bacterial colonies. Final culture results of the 5 comparative articles revealed 2 of 5 were contaminated with bacterial colonies. The absolute risk reduction is 40%, or a 40% rate of contamination drops to a 0% rate of contamination when the TTN catheter deployment was used. The risk ratio achieved was 1.67, indicating catheters placed using the OTN deployment were 1.67 times more like to be contaminated than the TTN deployed catheters. Conclusion: In this present ovine study, the data revealed that use of a novel TTN approach resulted in less contamination than the more traditional OTN approach. Traditional OTN devices, developed over 70 years ago, are at inherent risk of insertion-related contact contamination. The results of this research, as well as previously published studies, point toward considering physical catheter protection strategies such as TTN devices as a potential alternative to OTN devices.

Publisher

Mark Allen Group

Subject

General Nursing

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3