Reliability and validity of a smartphone goniometer application for measuring the quadriceps angle in healthy women: a cross-sectional study

Author:

Aafreen Aafreen1,Khan Ashfaque1,Khan Abdur Raheem1,Ahmad Ausaf2,Parween Saba3,Maurya Neeraj Kumar1,Alshehri Mohammed M4,Shaphe Mohammad Abu4,Ahmed Hashim5,Mirza Hadia1

Affiliation:

1. Department of Physiotherapy, Integral University, Lucknow, India

2. Department of Community Medicine, Integral University, Lucknow, India

3. Department of Physiotherapy, Al-Karim University, Katihar, India

4. Physical Therapy Department, College of Applied Medical Sciences, Jazan University, Jazan, Saudi Arabia

5. Department of Physiotherapy, College of Applied Medical Science, Najran University, Najran, Saudi Arabia

Abstract

Background/Aims The quadriceps angle, which depicts the quadriceps muscle's mechanical effect on the knee, is frequently used as an assessment metric when diagnosing a variety of knee-related issues. Smartphone goniometer applications have clinical assessment capabilities that can be used instead of the universal goniometer. The aim of this study was to analyse the criterion validity and inter- and intra-rater reliability of a smartphone goniometer application for measuring the quadriceps angle. Methods A total of 50 typically healthy women were included in this study. The quadriceps angle was evaluated with the universal goniometer as the gold standard and the Angulus smartphone goniometer application on each participant. The intraclass correlation coefficient and 95% confidence intervals were used to analyse reliability, while the standard error of the mean was used to calculate precision. Bland-Altman plots and 95% limits of agreement were used to establish the levels of agreement between the smartphone goniometer application and the universal goniometer. The Pearson correlation coefficient was used to quantify the smartphone goniometer application criterion validity in comparison to the universal goniometer. Results The smartphone goniometer application had good intra-rater reliability (intraclass correlation coefficient 0.99; 95% confidence interval 0.96–1) and inter-rater reliability (intraclass correlation coefficient 0.98; 95% confidence interval 0.94–1). A strong and significant correlation was found between the universal goniometer and the smartphone goniometer application, showing good criterion validity (r=0.99; 95% confidence interval 0.98–0.99; P=0.006). Conclusions The use of the smartphone goniometer application to measure the quadriceps angle was valid and demonstrated excellent intra- and inter-rater reliability levels. Implications for practice The smartphone goniometer application can be used in clinical practice as a valid and reliable quadriceps angle measurement tool.

Publisher

Mark Allen Group

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3