Comparison of 2-octyl cyanoacrylate with polyester mesh with standard suture and staples in total knee and hip arthroplasty

Author:

Koyama Suguru1,Tensho Keiji1,Takashimizu Ikkei2,Aoki Tetsuhiro3,Shimodaira Hiroki1,Iwaasa Tomoya1,Horiuchi Hiroshi4,Saito Naoto5,Yuzuriha Shunsuke2,Takahashi Jun1

Affiliation:

1. Department of Orthopedic Surgery, Shinshu University School of Medicine, 3-26-1, Asahi, Matsumoto, Nagano 390-8621, Japan

2. Department of Plastic and Reconstructive Surgery, Shinshu University School of Medicine, 3-26-1, Asahi, Matsumoto, Nagano 390-8621, Japan

3. Suwa Red Cross Hospital, 5-11-50, Kogandoori, Suwa, Nagano 392-8510, Japan

4. Department of Rehabilitation, Shinshu University Hospital, 3-26-1, Asahi, Matsumoto, Nagano 390-8621, Japan

5. Institute for Biomedical Sciences, Shinshu University School of Medicine, 3-26-1, Asahi, Matsumoto, Nagano 390-8621, Japan

Abstract

Objective: The use of 2-octyl cyanoacrylate with polyester mesh (OCA-M) has become common in total hip and knee arthroplasty (THA, TKA). We aimed to compare the safety and cosmetic outcomes between OCA-M and standard suture techniques and staples, and determine whether OCA-M can safely be used for TKA. Method: Inclusion criteria were patients who underwent THA or TKA from January 2010 to October 2011 (Suture group), November 2011 to August 2013 (Staple group), March 2017 to September 2018 (OCA-M group). Exclusion criteria was loss of imaging data. Complications during hospitalisation (early complication) and after discharge (late complication) were compared in groups. Plastic and orthopaedic surgeons performed cosmetic evaluations with the modified Vancouver Scar Scale (VSS) and Likert scale at three and six months postoperatively and compared in groups. Results: A total of 249 arthroplasties (suture group=88 patients; staple group=94 patients; OCA-M group=67 patients) were included in the study. The OCA-M group had a significantly lower early complication rate than the suture group (p=0.015). For THA, the OCA-M group had a significantly lower total complication rate than the suture group (p=0.048). For TKA, there was no significant difference among the three groups. The complication rate in the OCA-M group showed no significant difference between THA/TKA. With regards to the VSS, the OCA-M group was significantly better for cosmetic qualities than the suture group (p=<0.001, p=0.021 at three and six months, respectively). For the Likert scale, the OCA-M group was also significantly better for cosmetic qualities than the suture group and staple group (suture–OCA-M, p=0.003 (three months), p=<0.001 (six months); staple–OCA-M, p=0.027 (three months)). Conclusion: In this study, the OCA-M complication rate was low compared to suturing and similar to stapling. Moreover, better cosmetic outcomes were achieved compared to suturing and stapling.

Publisher

Mark Allen Group

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3