Affiliation:
1. Angel Animal Hospital, 2827–1, Furushiro, Yatsushiro, Kumamoto 866–0043 Japan
Abstract
Glomerular filtration rate (GFR) was estimated by plasma clearance of iohexol (PCio) in 52 conscious cats presented for a variety of reasons to Angel Animal Hospital over a 2-year period. Cats were divided into four groups according to their clinical conditions and reasons for measuring PCio. The median PCio (ml/min/kg) was 3.68 in normal cats (NM), 2.39 in cats with suspected renal disease (SP), 1.35 in cats referred to confirm renal dysfunction (RD), and 0.84 in cats with apparent clinical signs of renal failure (RF). There was a significant difference between the results for each group. The respective medians of blood urea nitrogen (BUN) and plasma creatinine concentration (Pcr) (mg/dl) were 15 and 1.40 in NM cats, 21 and 1.71 in SP cats, 30 and 2.20 in RD cats, and 48 and 3.30 in RF cats. The reference values of BUN and Pcr were 21 ± 7 mg/dl and 1.5 ± 0.4 mg/dl (mean ± SD). Diminished renal function could not be detected in SP cats by either BUN or Pcr, while a marked decrease of GFR was demonstrated before BUN and Pcr increased, indicating the insensitivity of BUN and Pcr in detecting renal dysfunction in cats. PCio can be performed non-invasively in conscious cats, which improves the veterinarian's ability to detect early stages of chronic renal disease.
Cited by
37 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献