Inaccuracy of the FloTrac/Vigileo™ System in Patients With Low Cardiac Index
Author:
Publisher
Elsevier BV
Subject
Anesthesiology and Pain Medicine,Cardiology and Cardiovascular Medicine
Reference28 articles.
1. Uncalibrated arterial pressure waveform analysis for cardiac output monitoring is biased by low peripheral resistance in patients with intracranial haemorrhage;Junttila;Br J Anaesth,2011
2. Evaluation of an uncalibrated arterial pulse contour cardiac output monitoring system in cirrhotic patients undergoing liver surgery;Biancofiore;Br J Anaesth,2009
3. Evaluation of a new software version of the FloTrac/Vigileo (version 3.02) and a comparison with previous data in cirrhotic patients undergoing liver transplant surgery;Biancofiore;Anesth Analg,2011
4. Performance of cardiac output measurement derived from arterial pressure waveform analysis in patients requiring high-dose vasopressor therapy;Metzelder;Br J Anaesth,2011
5. Clinical comparison of an echocardiograph-derived versus pulse counter-derived cardiac output measurement in abdominal aortic aneurysm surgery;Kusaka;J Cardiothorac Vasc Anesth,2012
Cited by 18 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献
1. At the Right Place, at the Right Time. Reply to Vetrugno et al. Comparison between FlowTrac and Pulmonary Arterial Catheter in Off-Pump Cardiac Surgery Patients: “Why Did We Miss Our Appointment?”. Comment on “Oh et al. Comparison between Fourth-Generation FloTrac/Vigileo System and Continuous Thermodilution Technique for Cardiac Output Estimation after Time Adjustment during Off-Pump Coronary Artery Bypass Graft Surgery: A Retrospective Cohort Study. J. Clin. Med. 2022, 11, 6093”;Journal of Clinical Medicine;2023-09-05
2. Accuracy of Cardiac Output Measured by Fourth-Generation FloTrac and LiDCOrapid, and Their Characteristics Regarding Systemic Vascular Resistance in Patients Undergoing Cardiac Surgery;Journal of Cardiothoracic and Vascular Anesthesia;2023-07
3. Validation of cardiac output estimation using the fourth-generation FloTrac/EV1000™ system in patients undergoing robotic-assisted off-pump coronary artery bypass surgery;Heart and Vessels;2022-10-01
4. Accuracy and Trending Ability of Cardiac Index Measured by the CNAP System in Patients Undergoing Abdominal Aortic Aneurysm Surgery;Journal of Cardiothoracic and Vascular Anesthesia;2021-05
5. Minimally Invasive Hemodynamic Assessment during Obstetric Hysterectomy for Invasive Placentation with Epidural Anesthesia;Anesthesiology Research and Practice;2020-10-28