Stability of alteplase for ultrasound-facilitated catheter-directed thrombolysis

Author:

Fanikos John1ORCID,Marquis Kathleen1,Buckley Leo1ORCID,Tran Lena K.1ORCID,McLaughlin Kevin1ORCID,Golash Abby Jane1ORCID,Campia Umberto2ORCID,Piazza Gregory2ORCID,Connors Jean M.3ORCID,Goldhaber Samuel Z.2

Affiliation:

1. Department of Pharmacy, Brigham and Women’s Hospital, Boston, MA;

2. Division of Cardiovascular Medicine, and

3. Division of Hematology, Department of Medicine, Brigham and Women’s Hospital, Harvard Medical School, Boston, MA

Abstract

Abstract Ultrasound-facilitated catheter-directed thrombolysis is used with low-dose alteplase to treat pulmonary embolism. This reduces the risk of bleeding that accompanies systemic administration of higher alteplase doses. Some studies suggest that alteplase given over 2 to 6 hours is safe and effective, but there are few data to support the stability of alteplase under these conditions. Therefore, we undertook this in vitro study to determine the duration of alteplase stability. Alteplase was prepared in solutions of 8 mg in 100 mL, 6 mg in 150 mL, and 8 mg in 200 mL. Solutions were administered through the EkoSonic Endovascular System (with and without ultrasound) to simulate administration over 2, 4, and 6 hours. Alteplase was assessed with reversed-phase high-performance liquid chromatography (RP-HPLC). Assays were performed at time 0 and at 30-minute intervals during simulated infusion. An enzyme-linked immunosorbent assay was used to measure alteplase concentrations at time 0 and at 15-minute intervals during simulated infusion. By using RP-HPLC in the absence of ultrasound, the alteplase concentration remained within 1% of the original concentration through 120, 240, and 360 minutes of infusion. By using RP-HPLC for measurement, alteplase in the presence of ultrasound degraded steadily over time to ∼90% of its original amount in 120 minutes, ∼80% in 240 minutes, and ∼70% in 360 minutes. The remaining alteplase was available for enzymatic activity. Alteplase solutions of 0.04 and 0.08 mg/mL degraded steadily over time during simulated ultrasound-facilitated catheter-directed administration. Alteplase that did not degrade remained available for enzymatic activity.

Publisher

American Society of Hematology

Subject

Hematology

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3